dense breast Archives - Revista Brasileira de Ginecologia e Obstetrícia

  • Original Article

    Comparison of Automated Breast Ultrasound and Hand-Held Breast Ultrasound in the Screening of Dense Breasts

    Revista Brasileira de Ginecologia e Obstetrícia. 2021;43(3):190-199

    Summary

    Original Article

    Comparison of Automated Breast Ultrasound and Hand-Held Breast Ultrasound in the Screening of Dense Breasts

    Revista Brasileira de Ginecologia e Obstetrícia. 2021;43(3):190-199

    DOI 10.1055/s-0040-1722156

    Views12

    Abstract

    Objective

    To compare hand-held breast ultrasound (HHBUS) and automated breast ultrasound (ABUS) as screening tool for cancer.

    Methods

    A cross-sectional study in patients with mammographically dense breasts was conducted, and both HHBUS and ABUS were performed. Hand-held breast ultrasound was acquired by radiologists and ABUS by mammography technicians and analyzed by breast radiologists. We evaluated the Breast Imaging Reporting and

    Data System

    (BI-RADS) classification of the exam and of the lesion, as well as the amount of time required to perform and read each exam. The statistical analysis employed was measures of central tendency and dispersion, frequencies, Student t test, and a univariate logistic regression, through the odds ratio and its respective 95% confidence interval, and with p<0.05 considered of statistical significance.

    Results

    Atotal of 440 patientswere evaluated. Regarding lesions,HHBUS detected 15 (7.7%) BI-RADS 2, 175 (89.3%) BI-RADS 3, and 6 (3%) BI-RADS 4, with 3 being confirmed by biopsy as invasive ductal carcinomas (IDCs), and 3 false-positives. Automated breast ultrasound identified 12 (12.9%) BI-RADS 2, 75 (80.7%) BI-RADS 3, and 6 (6.4%) BI-RADS 4, including 3 lesions detected by HHBUS and confirmed as IDCs, in addition to 1 invasive lobular carcinoma and 2 high-risk lesions not detected by HHBUS. The amount of time required for the radiologist to read the ABUS was statistically inferior compared with the time required to read the HHBUS (p<0.001). The overall concordance was 80.9%. A total of 219 lesions were detected, from those 70 lesions by both methods, 126 only by HHBUS (84.9% not suspicious by ABUS) and 23 only by ABUS.

    Conclusion

    Compared with HHBUS, ABUS allowed adequate sonographic study in supplemental screening for breast cancer in heterogeneously dense and extremely dense breasts.

    See more
    Comparison of Automated Breast Ultrasound and Hand-Held Breast Ultrasound in the Screening of Dense Breasts

Search

Search in:

Article type
abstract
book-review
brief-report
case-report
correction
editorial
letter
other
rapid-communication
research-article
review-article
Section
Arigos Originais
Article
Artigo de Revisão
Original Articles
Carta ao Editor
Carta ao Editor
Cartas
Case Report
Case Reports
Caso e Tratamento
Clinical Consensus Recommendation
Corrigendum
Editoriais
Editorial
Equipamentos e Métodos
Errata
Erratas
Erratum
FEBRASGO POSITION STATEMENT
Febrasgo Statement
Febrasgo Statement Position
FIGO Statement
GUIDELINES
Integrative Review
Letter to Editor
Letter to the Editor
Métodos e Técnicas
Nota do Editor
Nota Prévia
Original Article
Original Article/Contraception
Original Article/Infertility
Original Article/Obstetrics
Original Article/Oncology
Original Article/Sexual Violence/Pediatric and Adolescent Gynecology
Original Article/Teaching and Training
Original Articles
Relato de Caso
Relato de Casos
Relatos de Casos
Reply to the Letter to the Editor
Resposta dos Autores
Resumo De Tese
Resumos de Tese
Resumos de Teses
Resumos dos Trabalhos Premiados no 50º Congresso Brasileiro de Ginecologia e Obstetrícia
Review
Review Article
Review Articles
Revisão
Short Communication
Special Article
Systematic Review
Técnica e Equipamentos
Técnicas e Equipamentos
Técnicas e Métodos
Trabalhos Originais
Year / Volume
2024; v.46
2023; v.45
2022; v.44
2021; v.43
2020; v.42
2019; v.41
2018; v.40
2017; v.39
2016; v.38
2015; v.37
2014; v.36
2013; v.35
2012; v.34
2011; v.33
2010; v.32
2009; v.31
2008; v.30
2007; v.29
2006; v.28
2005; v.27
2004; v.26
2003; v.25
2002; v.24
2001; v.23
2000; v.22
1999; v.21
1998; v.20
ISSUE