Summary
Revista Brasileira de Ginecologia e Obstetrícia. 2007;29(8):396-401
DOI 10.1590/S0100-72032007000800003
PURPOSE: to translate and to validate the Female Sexual Function Index (FSFI) for Brazilian pregnant women. METHODS: ninety-two pregnant women attended at a low risk prenatal clinic, with diagnosis of the pregnancy confirmed by precocious ultrasonography, participated in the research. Initially, we translated the FSFI questionnaire for Portuguese language (of Brazil) in agreement with the international criteria. Cultural, conceptual and semantics adaptations of FSFI were accomplished, because of the differences of the language, so that the pregnant women understood the subjects. All the patients answered FSFI twice, in the same day, with two different interviewers, with an hour interval from one to other interview. After 7 to 14 days, the questionnaire was applied again in a second interview. Reliability (internal intra and interobserver consistence) and the validity of the constructo (to demonstrate that questionnaire measures the sexual function) were appraised. RESULTS: Cultural adaptations were necessary for us to obtain the final version. The internal intra-observer (alpha of Chronbach) consistence of the several domains oscillated from moderate to strong (0,791 to 0,911) and the interobserver consistence varied from 0,791 to 0,914. In the validation of the constructo, were obtained moderate correlations to fort among the final scores (general) of FSFI and of Female Sexual Quotient (QS-F) that has the capacity to evaluate the feminine sexual function. CONCLUSIONS: FSFI was adapted to the Portuguese language and to the Brazilian culture, presenting significant reliability and validity; it could be included and used in future studies of the Brazilian pregnant sexual function.
Summary
Revista Brasileira de Ginecologia e Obstetrícia. 2006;28(1):38-43
DOI 10.1590/S0100-72032006000100007
PURPOSE: to determine the intraobserver and interobserver reproducibility of endometrial volume measurements using the VOCAL®-imaging program (Virtual Organ Computer-aided AnaLysis). METHODS: one three-dimensional (3-D) ultrasound dataset of the endometrium was obtained from each of five infertile women with different endometrial volumes. For each 3-D dataset, the endometrial volume was calculated by two different observers using the manual mode in four different rotational steps (30º, 15º, 9º and 6º). Ten measurements were obtained with each method and observer from each 3-D dataset. We have used one-way ANOVA and the Tukey post-test to verify the differences among means and the intraclass correlation coefficient to test reliability. RESULTS: rotational methods employing a rotation step of 30º were associated with lower endometrial volume readings in 3 of the 5 patients. There were no significant differences between the means obtained by the 15º, 9º or 6º step rotation. No significant difference was found between the means obtained by the two different observers. The intraclass correlation coefficients were significantly lower with 30º (all under 0.984) than with the other step rotations (all above 0.996). CONCLUSIONS: the use of a rotational step of 15º or less provides reliable readings of endometrial volume: there were no significant differences between the means calculated by the two observers, associated with highintraclass correlation coefficient (>0.996). We recommend the 15º step rotation because it is quicker to be performed than 6º and 9º.