Summary
Revista Brasileira de Ginecologia e Obstetrícia. 2009;31(12):615-620
DOI 10.1590/S0100-72032009001200007
PURPOSES: to evaluate the influence of maternal hemoglobin (Hb) levels in the patterns of fetal heart rate (FHR) and in the fetal biophysical profile (FBP) in term gestations. METHODS: pregnant women with anemia (Hb<11.0 g/dL) were prospectively evaluated between the 36th and the 40th week of gestation, from January 2008 to March 2009. The Control Group was composed of term and healthy pregnant women, with normal values of hemoglobin (Hb>11,0 g/dL). Cases of anomalies or fetal growing restrictions were excluded. The FHR evaluation was performed by computerized cardiotocography (8002 System-Sonicaid), and by record analysis during 30 minutes of exam. The FBP was done in all the patients. Student's, χ2 and Fisher's exact tests were used, with 0.05 significance level. RESULTS: The average of maternal Hb in the group with anemia (n=18) was 9.4 g/dL (DP=1.4 g/dL), and in the control group, 12.4g/dL (DP=1.3 g/dL). There has been no significant mean differences between groups concerning the cardiotocography parameters, respectively: basal FHR(131.3 versus 133.7 bpm, p=0.5), FHR accelerations > 10b pm (7.9 versus 8.2, p=0.866), FHR accelerations > 15 bpm (5.2 versus. 5.4, p=0.9), episodes of high variation of the FHR (17.1 versus 15.5 min, p=0,5), episodes of variation of the FHR (4.4 versus 3.6 min, p=06), and short term variation (10.5 versus 10.9 ms, p=0.5). In both groups, all patients presented normal FBP. CONCLUSIONS: this study suggests that light or moderate maternal anemia, without other maternal or fetal comorbidity, is not associated with abnormalities in the parameters of fetal biophysical profile and of the FHR analyzed by computerized cardiotocography.
Summary
Revista Brasileira de Ginecologia e Obstetrícia. 2006;28(8):453-459
DOI 10.1590/S0100-72032006000800003
PURPOSE: to analyze the fetal heart rate (FHR) and umbilical artery Dopplervelocimetry between 18th and 20th weeks of gestation in pregnant women complicated by pregestational diabetes mellitus. METHODS: twenty-eight pregnancies with pregestational diabetes and 27 normal pregnant women were analyzed prospectively, in a cross-sectional and case-control study. The inclusion criteria were the following: singleton pregnancy between 18 and 29 weeks, no other associated maternal diseases and no fetal abnormality. Ultrasonography was performed and FHR was calculated by the interval between the beginnings of two consecutive cardiac cycles, in the three umbilical artery Doppler sonograms, obtained in the umbilical cord near to the placental insertion, using color Doppler. Five consecutive FHR cycles from each sonogram were measured, to analyze mean FHR and its variation. The following Doppler indices were studied: systolic/diastolic ratio, pulsatility index (PI) and resistance index (RI). Student's t test and Mann-Whitney Utest were applied to comparative study. p values were considered significant when p<0.05. Results: no significant difference was observed in mean FHR between the studied groups (diabetic group: 149.2 bpm, control group: 147.2 bpm; p = 0.12). FHR variation revealed similar results between the groups (diabetic group: 5.3 bpm; control group: 5.3 bpm; p=0.50). No significant difference was found in the Doppler indices S/D (p=0.79), PI (p=0.25) and RI (p=0.71) between the groups. CONCLUSIONS: the absence of differences in FHR characteristics between the 18th and 20th gestational weeks indicates similar neurological maturation of FHR regulatory systems in this period, between fetuses of diabetic mothers and controls. Abnormalities in the uteroplacental resistance were not identified in the studied period, in pregnancies complicated by pregestational diabetes.
Summary
Revista Brasileira de Ginecologia e Obstetrícia. 2005;27(12):712-718
DOI 10.1590/S0100-72032005001200002
PURPOSE: to verify the fetal heart rate (FHR) patterns of large for gestational age (LGA) fetuses in pregnancies at term complicated by pregestational diabetes. METHODS: fetal surveillance was performed weekly in 64 fetuses of mothers with pregestational diabetes. Inclusion criteria were: diagnosis of pregestational diabetes mellitus, single pregnancy, alive fetus, absence of fetal anomalies, and computerized cardiotocography performed at the 37th week of gestation. Exclusion criteria included: postnatal diagnosis of fetal anomalies and delivery not performed at the local hospital. The FHR patterns were studied with computerized cardiotocography and the parameters were analyzed according to a fetal weight as LGA (birth weight above percentile 90). The cardiotocography parameters included: basal FHR, episodes of high variation, episodes of low variation, and short-term variation. RESULTS: forty-two patients fulfilled the proposed criteria. Ten (23.8%) newborns were LGA. Normal criteria were met in all performed examinations. FHR accelerations (above 15 bpm) were present in 7 (70%) LGA cases and in 29 (90.6%) non-LGA (p=0.135). Accelerations were more frequent in the non-LGA group (1.5±1.3 accelerations/10 min) when compared to LGA group (0.8±0.9 accelerations/10min, p=0.04, Mann-Whitney test). The high variation episodes were detected in all cases. The mean FHR variation in these episodes was different in the LGA group (16.2±2.5 bpm) when compared to the non-LGA group (19.7±4.2 bpm, p=0.02, Mann-Whitney test). CONCLUSION: the FHR patterns of non-LGA (higher frequency of accelerations and higher FHR variation in the high variation episodes) reflect parameters commonly analyzed by traditional cardiotocography of a healthy fetus. This fact appears to confirm the patterns of better oxygen supply to the fetuses less compromised by diabetes in pregnancy.
Summary
Revista Brasileira de Ginecologia e Obstetrícia. 2004;26(5):391-398
DOI 10.1590/S0100-72032004000500008
OBJECTIVE: to analyze the maternal blood pressure and heart rate variation of primigravid women during labor and early puerperium. METHODS: sixty primigravid women were included in the study, and submitted to ambulatory blood pressure monitoring (ABPM) with SpaceLabs 90207 monitor during labor and the first 12 h of puerperium. The records of blood pressure and heart rate were done every 15 min during labor and every 30 min during the first 12 h of puerperium. Three periods during labor (until cervix dilated 7 cm, cervix dilated between 8 cm and total dilatation, and delivery period) and two during puerperium (first and twelfth hours), were analyzed. First of all the results were analyzed without considering the kind of analgesia used and then the patients were divided into three groups, according to the anesthetic technique: local, lumbar extradural or subarachnoid. Results were analyzed by one-way analysis of variance (ANOVA) and paired Student's t-test for blood pressure and heart rate in each group during labor and puerperium. The nonpaired Student's t-test was used to compare different groups. A p value < 0.05 was regarded as statistically significant. RESULTS: when the results were analyzed without considering the analgesic procedure, the values of systolic blood pressure during labor were significantly higher than in early puerperium. During labor, systolic blood pressure values were higher in the periods of later cervical dilatation and delivery than during early cervical dilatation. In the 12th h of puerperium the systolic blood pressure was lower than in the first hour. Diastolic blood pressure did not change during labor and was higher than in early puerperium. Heart rate increased during labor and decreased during puerperium. The systolic and diastolic blood pressure and heart rate were the same both in local or lumbar extradural anesthesia groups; however, in the subarachnoid group the systolic and diastolic blood pressure did not change during labor. CONCLUSIONS: labor increased systolic blood pressure and heart rate. During labor, systolic and diastolic blood pressure were higher than in early puerperium. Both blood pressure and heart rate significantly fell from the first to the 12th hour of puerperium. The different anesthetic techniques did not affect blood pressure or heart rate, as compared with the primigravid group when the anesthetic technique was not taken into consideration.
Summary
Revista Brasileira de Ginecologia e Obstetrícia. 2003;25(3):163-167
DOI 10.1590/S0100-72032003000300004
PURPOSE: to show longitudinally the profiles and parameters of pressure rhythm and heart rate in normotensive pregnant women during the three trimesters of pregnancy. PATIENTS AND METHODS: the longitudinal and random study involved 23 normotensive pregnant women, mean age 23.3 ± 3.9 years, recruited from the prenatal clinics of the "Maternidade-Escola Hilda Brandão - Santa Casa de Belo Horizonte/MG". Ambulatory blood pressure monitoring was done every three months (up to 14 weeks, between 18 and 28 weeks and between 32 and 40 weeks, using the SpaceLabs monitor, model 90207. RESULTS: a significant increase (p<0.01) in the 24-h systolic (115 and 104 mmHg), diastolic (73 and 61 mmHg) and average diurnal and nocturnal blood pressures (87 and 77 mmHg respectively), was noticed in the third trimester of pregnancy. Mother's diurnal blood pressure and heart rate (83, 84 and 87 mmHg; 94, 95 and 93 bpm) were significantly higher than the nocturnal measurements (72, 72 and 77 mmHg; 74, 79 and 79 bpm), in the three trimesters. Mother's heart frequency did not change during progress of pregnancy. CONCLUSION: increase in blood pressure during the third trimester of pregnancy could be shown. Maternal daily and diurnal heart rate did not change when the three trimesters were compared. The nocturnal heart rate was significantly lower in the first trimester as compared to the other trimesters.