Middle cerebral arteries Archives - Revista Brasileira de Ginecologia e Obstetrícia

  • Artigos Originais

    The influence of the site of middle cerebral doppler flow analysis

    Revista Brasileira de Ginecologia e Obstetrícia. 2005;27(3):137-142

    Summary

    Artigos Originais

    The influence of the site of middle cerebral doppler flow analysis

    Revista Brasileira de Ginecologia e Obstetrícia. 2005;27(3):137-142

    DOI 10.1590/S0100-72032005000300007

    Views2

    PURPOSE: to evaluate if there is any difference between Doppler indexes in the middle cerebral artery in two different sites of insonation in healthy patients and in patients with diseases. METHODS: a random prospective survey, in the period from June 2003 to March 2004 that analyzed the Doppler indexes of 100 patients: patient group (n = 50) included patients admitted to Clemente Farias University Hospital, which is part of UNIMONTES-MG, havinfg as inclusion criteria: to be in the 28th to 34th gestational week, diagnosis of chronic arterial hypertension, pre-eclampsia, intrauterine growth restriction. As control group, 50 healthy pregnant patients between the 28th and the 34th week, originary from SEMESP's clinic. The Doppler variables were the resistance index (RI), the pulsatility index (PI) and the relation systole/diastole (SD). All three Doppler indexes were assessed at two different sites of the cerebral artery: the first measurement in the diencephalons region, soon after the beginning of the middle cerebral artery and the second on a distal location in the telencephalon. The median Doppler indexes in the patient group in the first and second measurements were 1.55 and 1.69 for the PI, 0.77 and 0.79 for RI and 4.29 and 4.86 for SD, respectively. In the control group, the values were 1.73 and 1.86 for the PI; 0.83 and 0.79 for RI and 5.83 and 5.46 for SD. There were no differences between sites with a p value of 0.38, 0.29 and 0.39 for PI, RI and SD, respectively. In 15t fetuses with centralization (brain sparing effects), in the diencephalon the median indexes were 1.02 for PI, 0.63 for RI and 2.68 for SD. In the epencephalon the median indexes were 0.95 for IP, 0.62 for RI and 2.44 for SD. There were no differences between sites, with a p value of 0.53 for PI; 0.56 for IR and 0.31 for SD. The Doppler index site of assessment in the middle cerebral arteries does not interfere with the results.

    See more
    The influence of the site of middle cerebral doppler flow analysis

Search

Search in:

Article type
abstract
book-review
brief-report
case-report
case-report -
correction
editorial
editorial -
letter
letter -
other
other -
rapid-communication
research-article
research-article -
review-article
review-article -
Section
Arigos Originais
Artigo de Revisão
Original Articles
Carta ao Editor
Carta ao Editor
Cartas
Case Report
Case Reports
Caso e Tratamento
Clinical Consensus Recommendation
Corrigendum
Editoriais
Editorial
Editorial
Equipamentos e Métodos
Errata
Erratas
Erratum
Febrasgo Position Statement
Febrasgo Statement
Febrasgo Statement Position
FIGO Statement
GUIDELINES
Integrative Review
Letter to Editor
Letter to Editor
Letter to the Editor
Letter to the Editor
Métodos e Técnicas
Nota do Editor
Nota Prévia
Original Article
Original Article/Contraception
Original Article/Infertility
Original Article/Obstetrics
Original Article/Oncology
Original Article/Sexual Violence/Pediatric and Adolescent Gynecology
Original Article/Teaching and Training
Original Articles
Original Articles
Relato de Caso
Relato de Casos
Relatos de Casos
Reply to the Letter to the Editor
Resposta dos Autores
Resumo De Tese
Resumo De Tese
Resumos de Tese
Resumos de Tese
Resumos de Teses
Resumos de Teses
Resumos dos Trabalhos Premiados no 50º Congresso Brasileiro de Ginecologia e Obstetrícia
Review
Review Article
Review Articles
Revisão
Revisão
Short Communication
Special Article
Systematic Review
Técnica e Equipamentos
Técnicas e Equipamentos
Técnicas e Métodos
Trabalhos Originais
Year / Volume
2024; v.46
2023; v.45
2022; v.44
2021; v.43
2020; v.42
2019; v.41
2018; v.40
2017; v.39
2016; v.38
2015; v.37
2014; v.36
2013; v.35
2012; v.34
2011; v.33
2010; v.32
2009; v.31
2008; v.30
2007; v.29
2006; v.28
2005; v.27
2004; v.26
2003; v.25
2002; v.24
2001; v.23
2000; v.22
1999; v.21
1998; v.20
ISSUE