Infant, very low birth weight/mortality Archives - Revista Brasileira de Ginecologia e Obstetrícia

  • Artigos Originais

    Correlation between antenatal corticosteroid therapy, resuscitation and mortality in very low birth weight infants

    Rev Bras Ginecol Obstet. 2014;36(5):211-215

    Summary

    Artigos Originais

    Correlation between antenatal corticosteroid therapy, resuscitation and mortality in very low birth weight infants

    Rev Bras Ginecol Obstet. 2014;36(5):211-215

    DOI 10.1590/S0100-7203201400050005

    Views1

    PURPOSE:

    To evaluate the correlation between the use of antenatal corticosteroid therapy (AC), the frequency of resuscitation in delivery room and mortality of newborn infants under 1,500 g and gestational age less than or equal to 34 weeks.

    METHODS:

    A cohort study was conducted on all newborn infants under 1,500 g and with a gestational age less than or equal to 34 weeks admitted at the neonatal ICU between January 2006 and December 2011. Newborns who had congenital anomalies, genetic syndromes, congenital infections and those who were transferred to or came from other institutions were excluded. The studied infants were divided into 2 groups: those who received (n=182) and those who did not receive (n=38) AC. The main outcomes studied were the necessity of neonatal resuscitation, the presence of the main neonatal diseases and mortality during hospitalization. The means of the variables were compared using Student's t-test or non-parametric test and frequencies were compared by χ2test with Fisher's correction. The variables that presented difference between groups were assessed by logistic regression. The Statistical Package for the Social Sciences (SPSS) 16.0 was used and the significance level was set at 0.05.

    RESULTS:

    In this study, 220 patients were evaluated. The groups were similar concerning birth weight, gestational age and the presence of the main neonatal morbidity during hospitalization. The infants who received antenatal corticosteroids showed lower mortality (OR=3.0; 95%CI 1.4-6.5) and required less resuscitation (OR=2.4; 95%CI 1.1-5.0). Besides, they required less advanced resuscitation procedures, such as tracheal cannula (OR=3.7; 95%CI 1.7-7.6), cardiac massage (OR=5.7; 95%CI 2.0-16.5) and medications (OR=8.9; 95%CI 2.0-39.4).

    CONCLUSIONS:

    The use of antenatal corticosteroids reduced the need for resuscitation in delivery room, especially advanced procedures, and reduced the mortality in the studied groups.

    See more

Search

Search in:

Article type
abstract
book-review
brief-report
case-report -
correction
editorial
editorial -
letter
letter -
other -
rapid-communication
research-article
research-article -
review-article
review-article -
Section
Abstracts of Awarded Papers at the 50th Brazilian Congress of Gynecology and Obstetrics
Artigo de Revisão
Original Articles
Carta ao Editor
Case Report
Case Report and Treatment
Clinical Consensus Recommendation
Editorial
Editorial
Equipments and Methods
Erratum
Febrasgo Position Statement
Letter to the Editor
Methods and Techniques
Nota do Editor
Original Article
Original Article/Contraception
Original Article/Infertility
Original Article/Obstetrics
Original Article/Oncology
Original Article/Sexual Violence/Pediatric and Adolescent Gynecology
Original Article/Teaching and Training
Original Articles
Original Articles
Previous Note
Relato de Caso
Relatos de Casos
Resposta dos Autores
Resumo De Tese
Resumos de Teses
Review Article
Short Communication
Special Article
Systematic Review
Técnicas e Equipamentos
Thesis Abstract
Trabalhos Originais
Year / Volume
2024; v.46
2023; v.45
2022; v.44
2021; v.43
2020; v.42
2019; v.41
2018; v.40
2017; v.39
2016; v.38
2015; v.37
2014; v.36
2013; v.35
2012; v.34
2011; v.33
2010; v.32
2009; v.31
2008; v.30
2007; v.29
2006; v.28
2005; v.27
2004; v.26
2003; v.25
2002; v.24
2001; v.23
2000; v.22
1999; v.21
1998; v.20
ISSUE