Revista Brasileira de Ginecologia e Obstetrícia. 2016;38(1):20-26
To evaluate the correlation of the levels of fructosamine and of glycated hemoglobin (HbA1c) with the frequency of blood glucose self-monitoring values out of the treatment target range in pregnant women with diabetes mellitus.
We performed an observational, retrospective, cross-sectional study, including all pregnant women with diabetes who attended prenatal care visits at a tertiary teaching hospital during the year of 2014 and who presented at least 20 days of blood glucose self-monitoring prior to assessment of serum levels of fructosamine and HbA1c. Capillary blood glucose values out of the treatment target range were considered "hypoglycemia" when lower than 70 mg/dL and "hyperglycemia" when above the glycemic therapeutic target. We evaluated the correlation of the levels of fructosamine and of HbA1c with the frequencies of hyperglycemia and hypoglycemia recorded in the glucometer device by performing Tau-b of Kendall correlation tests. Next, linear regression tests were performed between the levels of HbA1c and of fructosamine and the frequencies of hypoglycemia and hyperglycemia.
We included 158 pregnant women, from whom 266 blood samples were obtained for assessing fructosamine and HbA1c levels. Measurements of fructosamine and of HbA1c presented, respectively, Kendall's τ coefficient of 0.29 (p < 0.001) and 0.50 (p < 0.001) regarding the frequency of hyperglycemia, and of 0.09 (p = 0.046) and 0.25 (p < 0.001) regarding the frequency of hypoglycemia. In the linear regression model, levels of fructosamine and of HbA1c respectively presented determination coefficients R2 = 0.265 (p < 0.001) and R2 = 0.513 (p < 0.001) for the prediction of hyperglycemia, and R2 = 0.033 (p = 0.003) and R2 = 0.059 (p < 0.001) for the prediction of hypoglycemia.
Levels of fructosamine and of HbA1c presented a weak to moderate correlation with the frequencies of hyperglycemia and hypoglycemia at blood glucose self-monitoring and were not able to accurately translate the deviations from the glycemic goals in pregnant women with diabetes.
Summary
Revista Brasileira de Ginecologia e Obstetrícia. 2010;32(2):66-71
DOI 10.1590/S0100-72032010000200003
PURPOSE: to evaluate the importance of maternal plasma concentration of fructosamine as an indicator of fetal congenital cardiopathies in pregnancies complicated by diabetes mellitus. METHODS: this was a retrospective study conducted on 91 pregnant women with diabetes mellitus who underwent routine fetal echocardiography at a university reference center in fetal medicine. Sixty-five patientes who presented pre-gestational diabetes mellitus and plasma fructosamine level were registered in the medical records prior to the ultrasound exam. The first measurement recorded was compared with the result of routine fetal echocardiography, carried out by a specialist physician of the service. The presence or absence of echocardiographic findings of congenital cardiopathies (EFCC) was related to plasma levels of fructosamine by the mean t-test and its accuracy for EFCC was verified by the ROC curve. Plsama fructosamine concentrations of 2.68, 2.9 and 2.23 mmol/L, which are, respectively, the local reference laboratory values, the value of the kit employed for measurement and the one of highest overall accuracy, were discussed as the cut-off values. RESULTS: EFCC was found in 52.3% of the fetuses. The first measurement of fructosamine, during the prenatal care period, was performed, on average, at 20.4±8.0 weeks of pregnancy. The maternal concentration ability of the fructosamine to identify fetuses with EFCC was significant (p<0.0001) and had an area under the ROC curve of 0.78 (95%CI=0.66-0.89). The 2.9 mmol/L plasma concentration of fructosamine revealed EFCC with better specificity, but with a higher percentage of false-negative results (96.8 and 55.9%). Values above 2.68 mmol/L were associated with a probability of 4.6 to identify fetuses with EFCC compared with lower values, with 58.8% of sensitivity and 87.1%, specificity. The value of 2.23 mmol/L proved to be the most overall accurate of the three values suggested, with a sensitivity of 88.2% in the identification of fetuses with echocardiographic abnormalities. CONCLUSIONS: it is possible to use a second trimester plasma fructosamine level to refer high risk pregnant women to a reference center of fetal echocardiography. These findings are important for the management of women with diabetes mellitus who initiate late prenatal care.