Echocardiography Archives - Revista Brasileira de Ginecologia e Obstetrícia

  • Artigos Originais

    Fetal heart disease and coping strategies

    Revista Brasileira de Ginecologia e Obstetrícia. 2011;33(9):227-233

    Summary

    Artigos Originais

    Fetal heart disease and coping strategies

    Revista Brasileira de Ginecologia e Obstetrícia. 2011;33(9):227-233

    DOI 10.1590/S0100-72032011000900002

    Views6

    PURPOSE: To evaluate the coping strategies of women facing a diagnosis of fetal heart disease. METHODS: We interviewed 50 women who had received a diagnosis of fetal heart disease. For data collection we used a semi-directed and Coping Strategy Inventory. The interview was conducted, on average, 22 days after the diagnosis. RESULTS: When asked how they felt about the baby, 56.0% reported concern and fragility, while the remaining 44.0% said they were happy and well. The strategies most used by women were problem solving (73.0%), social support (69.1%) and escape/avoidance (62.7%), and the least used strategy was removal (17.3%). It was found that women with partners, as well as those with 1 or 2 children, used more the problem-solving strategy (p<0.05). CONCLUSIONS: The active coping strategies, focused on problem solving and seeking social support, coupled with the responsibility and the need for specific care for the survival and welfare of the baby, brought about a closer relationship with the pregnancy, strengthening the maternal-fetal bond.

    See more
  • Artigos Originais

    Fetal cardiac rhabdomyoma: analysis of five cases

    Revista Brasileira de Ginecologia e Obstetrícia. 2010;32(4):156-162

    Summary

    Artigos Originais

    Fetal cardiac rhabdomyoma: analysis of five cases

    Revista Brasileira de Ginecologia e Obstetrícia. 2010;32(4):156-162

    DOI 10.1590/S0100-72032010000400002

    Views9

    PURPOSE: to analyze the differential diagnosis, follow-up and therapeutic approach in five cases of primary cardiac tumors diagnosed during the prenatal period. METHODS: during the period from January 1997 to December 2008, 7989 pregnant women were submitted to morphological ultrasound due to the presence of risk factors for fetal malformations. Fetuses with hyperechogenic intracardiac masses larger than 1 mm diagnosed by ultrasound evaluation of the fetal heart, were selected for study. The differential diagnosis between the different tumor types was made on the basis of the ultrasound characteristics of the masses. RESULTS: five fetuses with hiperechogenic intracardiac masses were diagnosed, corresponding to a 0.06% prevalence rate. Gestational age ranged from 28 to 36 weeks (mean: 31), and maternal age ranged from 23 to 45 years (mean: 34,2). The most frequent location of the masses was the left ventricle (100%). Echographically, all masses were single or multiple, hyperechogenic, homogeneous and well delimited, compatible with a diagnosis of rhabomyoma. In cases in which the diameters of the masses were less than 20 mm, an expectant conduct was followed and no complications occurred during the prenatal period. One case with a huge tumor presented arrhythmia and cardiac insufficiency during the 35 gestational weeks, and the interruption of pregnancy was indicated. Tuberous sclerosis was associated in four cases (80%) and the diagnosis was confirmed during the postnatal follow-up. CONCLUSIONS: fetal morphological ultrasonography is the main form of early detection of primary cardiac tumors. The fetal cardiac evaluation is of fundamental importance for the differential morphological characterization of cardiac masses and for the evaluation of cardiac function. Rhabdomyomas are the most common type of fetal tumor. An expectant pre and postnatal conduct is followed, with a low risk of complications and with the possibility of spontaneous regression in most cases. Postnatal clinical follow-up is mandatory due to the high frequency of associated tuberous sclerosis.

    See more
    Fetal cardiac rhabdomyoma: analysis of five cases
  • Artigos Originais

    Congenital cardiopathies screening associated with diabetes mellitus using maternal fructosamine plasma concentration

    Revista Brasileira de Ginecologia e Obstetrícia. 2010;32(2):66-71

    Summary

    Artigos Originais

    Congenital cardiopathies screening associated with diabetes mellitus using maternal fructosamine plasma concentration

    Revista Brasileira de Ginecologia e Obstetrícia. 2010;32(2):66-71

    DOI 10.1590/S0100-72032010000200003

    Views6

    PURPOSE: to evaluate the importance of maternal plasma concentration of fructosamine as an indicator of fetal congenital cardiopathies in pregnancies complicated by diabetes mellitus. METHODS: this was a retrospective study conducted on 91 pregnant women with diabetes mellitus who underwent routine fetal echocardiography at a university reference center in fetal medicine. Sixty-five patientes who presented pre-gestational diabetes mellitus and plasma fructosamine level were registered in the medical records prior to the ultrasound exam. The first measurement recorded was compared with the result of routine fetal echocardiography, carried out by a specialist physician of the service. The presence or absence of echocardiographic findings of congenital cardiopathies (EFCC) was related to plasma levels of fructosamine by the mean t-test and its accuracy for EFCC was verified by the ROC curve. Plsama fructosamine concentrations of 2.68, 2.9 and 2.23 mmol/L, which are, respectively, the local reference laboratory values, the value of the kit employed for measurement and the one of highest overall accuracy, were discussed as the cut-off values. RESULTS: EFCC was found in 52.3% of the fetuses. The first measurement of fructosamine, during the prenatal care period, was performed, on average, at 20.4±8.0 weeks of pregnancy. The maternal concentration ability of the fructosamine to identify fetuses with EFCC was significant (p<0.0001) and had an area under the ROC curve of 0.78 (95%CI=0.66-0.89). The 2.9 mmol/L plasma concentration of fructosamine revealed EFCC with better specificity, but with a higher percentage of false-negative results (96.8 and 55.9%). Values above 2.68 mmol/L were associated with a probability of 4.6 to identify fetuses with EFCC compared with lower values, with 58.8% of sensitivity and 87.1%, specificity. The value of 2.23 mmol/L proved to be the most overall accurate of the three values suggested, with a sensitivity of 88.2% in the identification of fetuses with echocardiographic abnormalities. CONCLUSIONS: it is possible to use a second trimester plasma fructosamine level to refer high risk pregnant women to a reference center of fetal echocardiography. These findings are important for the management of women with diabetes mellitus who initiate late prenatal care.

    See more
    Congenital cardiopathies screening associated with diabetes mellitus using maternal fructosamine plasma concentration
  • Artigos Originais

    Ultrasound examination, fetal echocardiography and prenatal outcome in HIV-positive pregnant women under antiretroviral therapy

    Revista Brasileira de Ginecologia e Obstetrícia. 2007;29(10):497-505

    Summary

    Artigos Originais

    Ultrasound examination, fetal echocardiography and prenatal outcome in HIV-positive pregnant women under antiretroviral therapy

    Revista Brasileira de Ginecologia e Obstetrícia. 2007;29(10):497-505

    DOI 10.1590/S0100-72032007001000002

    Views6

    PURPOSE: to evaluate fetal structural and/or functional abnormalities by ultrasound examination and fetal echocardiography, in pregnant women positive for human immunodeficiency virus (HIV). METHODS: we analyzed prospectively 109 HIV positive pregnant women under antiretroviral therapy (Study Group) and 200 low risk pregnant patients (Control Group). All of them were submitted to ultrasound scan and fetal and neonatal echocardiography once a month. The amniotic fluid volume, fetal growth, fetal structural and functional alteration and the perinatal outcome were evaluated. RESULTS: there were eight (7.3%) cases of fetal structural abnormality in the Study Group and two (1%) in the Control Group (p=0.616). There were four cases of congenital heart disease and four cases of hydronephrosis in the Study Group, with statistic significance (p=0.015) for the cardiac abnormalities. There were eight cases (7.3%) of oligohydramnios and 11 cases (10%) of polyhydramnios in the Study Group against two cases (1%) of oligohydramnios and none of polyhydramnios in the Control Group (p=0.004 and p<0.001). Eleven (10%) newborn babies were too small for their gestation age in the Study Group, against three (2.7%) in the Control Group (p=0,002). The incidence of preterm delivery was 8.7 and 2.5% in the Study and Control Groups respectively (p=0.041). It was observed six cases (5.5%) of fetal death in the Study Group and none in the Control Group (p=0.002). CONCLUSIONS: in the present study, we have observed higher prevalence of amniotic fluid volume and congenital heart abnormalities in the Study Group as compared to the Control Group. Statistical significance was found in both situations. The high fetal death rate found in the Study Group was probably due to fetal malformation, whereas the high prematurity rate and the prevalence of small size for the gestational age of the newborn babies were probably related to antiretroviral therapy, smoking and drug abuse.

    See more
  • Artigos Originais

    Screening and echocardiographic diagnosis of arrhythmias and congenital heart diseases in the fetus

    Revista Brasileira de Ginecologia e Obstetrícia. 2006;28(5):304-309

    Summary

    Artigos Originais

    Screening and echocardiographic diagnosis of arrhythmias and congenital heart diseases in the fetus

    Revista Brasileira de Ginecologia e Obstetrícia. 2006;28(5):304-309

    DOI 10.1590/S0100-72032006000500007

    Views8

    PURPOSE: to analyze the results of a screening and diagnostic program of arrhythmias and congenital heart disease in a reference hospital and the relevance of early diagnosis in the fetal and neonate evolution. METHODS: cardiac evaluation of 1159 fetuses was done in two different levels. Level I: by morphological ultrasound examination with the objective to detect the existence of either arrhythmias or structural cardiac malformations. Level II: by fetal echocardiography to establish the differential diagnosis. The results of level I in the arrhythmia group were compared with those of level II, and in the group with malformations the results of both levels were confronted with the neonate echocardiogram or necropsy. The kappa index was calculated to evaluate the concordance between the two levels. RESULTS: all detected arrhythmias in level I were confirmed in level II, there were no false negative cases and five patients with severe arrhythmia required pharmacological therapy. The diagnosis of structural malformation by level I had sensitivity of 72% and specificity of 98% and there were 28% of false-positive cases. In level II, the sensitivity and specificity of the diagnosis of congenital heart disease were 100 and 99%, respectively. The kappa index was 57% and indicated a moderate degree of concordance between the two levels. Fifty-one percent of the fetuses with diagnosis of cardiac malformations required pharmacological or invasive intervention immediately after birth. CONCLUSION: morphological ultrasound examination is a important tool in the screening of arrhythmias and congenital heart defects during fetal life. The sensitivity and specificity of the fetal echocardiogram were very high and the early diagnosis made it possible to treat the fetus with severe cardiac disease either during pregnancy or immediately after birth.

    See more
    Screening and echocardiographic diagnosis of arrhythmias and congenital heart diseases in the fetus

Search

Search in:

Article type
abstract
book-review
brief-report
case-report
correction
editorial
letter
other
rapid-communication
research-article
review-article
Section
Arigos Originais
Article
Artigo de Revisão
Original Articles
Carta ao Editor
Carta ao Editor
Cartas
Case Report
Case Reports
Caso e Tratamento
Clinical Consensus Recommendation
Corrigendum
Editoriais
Editorial
Equipamentos e Métodos
Errata
Erratas
Erratum
FEBRASGO POSITION STATEMENT
Febrasgo Statement
Febrasgo Statement Position
FIGO Statement
GUIDELINES
Integrative Review
Letter to Editor
Letter to the Editor
Métodos e Técnicas
Nota do Editor
Nota Prévia
Original Article
Original Article/Contraception
Original Article/Infertility
Original Article/Obstetrics
Original Article/Oncology
Original Article/Sexual Violence/Pediatric and Adolescent Gynecology
Original Article/Teaching and Training
Original Articles
Relato de Caso
Relato de Casos
Relatos de Casos
Reply to the Letter to the Editor
Resposta dos Autores
Resumo De Tese
Resumos de Tese
Resumos de Teses
Resumos dos Trabalhos Premiados no 50º Congresso Brasileiro de Ginecologia e Obstetrícia
Review
Review Article
Review Articles
Revisão
Short Communication
Special Article
Systematic Review
Técnica e Equipamentos
Técnicas e Equipamentos
Técnicas e Métodos
Trabalhos Originais
Year / Volume
2024; v.46
2023; v.45
2022; v.44
2021; v.43
2020; v.42
2019; v.41
2018; v.40
2017; v.39
2016; v.38
2015; v.37
2014; v.36
2013; v.35
2012; v.34
2011; v.33
2010; v.32
2009; v.31
2008; v.30
2007; v.29
2006; v.28
2005; v.27
2004; v.26
2003; v.25
2002; v.24
2001; v.23
2000; v.22
1999; v.21
1998; v.20
ISSUE