Collecting devices Archives - Revista Brasileira de Ginecologia e Obstetrícia

  • Trabalhos Originais

    Use of a modified ayre spatula in cervical cytology

    Revista Brasileira de Ginecologia e Obstetrícia. 1999;21(6):327-331

    Summary

    Trabalhos Originais

    Use of a modified ayre spatula in cervical cytology

    Revista Brasileira de Ginecologia e Obstetrícia. 1999;21(6):327-331

    DOI 10.1590/S0100-72031999000600005

    Views0

    Purpose: the authors modified the original Ayre spatula aiming at optimizing endocervical collection. The study verified if the capacity of the modified spatula in collecting endocervical cells is similar to that obtained by the combination brush-Ayre spatula and better than the Ayre spatula alone. Methods: a diagnostic and single-blind simple study was performed. The patients were randomly assigned to one of three collection groups (Ayre spatula, combination of brush-Ayre spatula and modified spatula). After excluding data of 25 patients, 276 smears were evaluated with attention to the presence of squamous, metaplastic, and columnar endocervical cells and their combination. In order to compare methods, the chi² test with corrected Yates values and the exact Fisher test were used. Results: the combination brush-Ayre spatula presented the best performance in the production of columnar endocervical cells. When compared to the combination of brush-Ayre spatula, the modified spatula produced less bleeding in the smears (chi² = 7.98; p = 0.004) and it was not statistically inferior in obtaining metaplastic cells (chi² = 2.97; p = 0.08). When compared to the Ayre spatula, it was statistically superior in obtaining columnar endocervical cells (chi² = 21.37; p = 0.000004) and presented a greater percentage of smears presenting squamous cells accompanied by metaplastic and/or columnar endocervical cells (chi² = 10.97; p = 0.0009). Conclusions: it was concluded that the modified spatula improved the quality of the sample obtained with the Ayre spatula alone, being able to be used in populations where the use of the brush was impossible.

    See more
    Use of a modified ayre spatula in cervical cytology

Search

Search in:

Article type
abstract
book-review
brief-report
case-report
case-report -
correction
editorial
editorial -
letter
letter -
other
other -
rapid-communication
research-article
research-article -
review-article
review-article -
Section
Arigos Originais
Artigo de Revisão
Original Articles
Carta ao Editor
Carta ao Editor
Cartas
Case Report
Case Reports
Caso e Tratamento
Clinical Consensus Recommendation
Corrigendum
Editoriais
Editorial
Editorial
Equipamentos e Métodos
Errata
Erratas
Erratum
Febrasgo Position Statement
Febrasgo Statement
Febrasgo Statement Position
FIGO Statement
GUIDELINES
Integrative Review
Letter to Editor
Letter to Editor
Letter to the Editor
Letter to the Editor
Métodos e Técnicas
Nota do Editor
Nota Prévia
Original Article
Original Article/Contraception
Original Article/Infertility
Original Article/Obstetrics
Original Article/Oncology
Original Article/Sexual Violence/Pediatric and Adolescent Gynecology
Original Article/Teaching and Training
Original Articles
Original Articles
Relato de Caso
Relato de Casos
Relatos de Casos
Reply to the Letter to the Editor
Resposta dos Autores
Resumo De Tese
Resumo De Tese
Resumos de Tese
Resumos de Tese
Resumos de Teses
Resumos de Teses
Resumos dos Trabalhos Premiados no 50º Congresso Brasileiro de Ginecologia e Obstetrícia
Review
Review Article
Review Articles
Revisão
Revisão
Short Communication
Special Article
Systematic Review
Técnica e Equipamentos
Técnicas e Equipamentos
Técnicas e Métodos
Trabalhos Originais
Year / Volume
2024; v.46
2023; v.45
2022; v.44
2021; v.43
2020; v.42
2019; v.41
2018; v.40
2017; v.39
2016; v.38
2015; v.37
2014; v.36
2013; v.35
2012; v.34
2011; v.33
2010; v.32
2009; v.31
2008; v.30
2007; v.29
2006; v.28
2005; v.27
2004; v.26
2003; v.25
2002; v.24
2001; v.23
2000; v.22
1999; v.21
1998; v.20
ISSUE