Você pesquisou por y - Revista Brasileira de Ginecologia e Obstetrícia

You searched for:"Tatiana Bernáth"

We found (1) results for your search.
  • Original Article

    Uterine Cervical Length Evaluation in the Standing and Recumbent Positions in Twin Pregnancies

    Rev Bras Ginecol Obstet. 2002;24(4):247-251

    Summary

    Original Article

    Uterine Cervical Length Evaluation in the Standing and Recumbent Positions in Twin Pregnancies

    Rev Bras Ginecol Obstet. 2002;24(4):247-251

    DOI 10.1590/S0100-72032002000400006

    Views0

    Purpose: to compare cervical length measurements in twin pregnancies obtained by transvaginal ultrasound examination in the recumbent and standing positions. Methods: fifty twin pregnancies underwent transvaginal ultrasound examinations to measure the cervical length with the women in recumbent and standing positions. The study was carried out between May 1999 and December 2000. The scans were repeated every 4 weeks and the total number of evaluations was 136. Two groups were analyzed: one included only the first ultrasound examinations carried out in each woman and the second group included all evaluations. Results: in the first group, cervical length measurements in the standing and recumbent positions correlated inversely with the gestational age (recumbent: r=-0.60; p<0.001; standing: r=-0.46; p=0.008). The mean measure in the recumbent position was 35.2 mm (SD=9.9 mm) and 33.4 mm (SD=9.5 mm) in the standing position. When the difference between the measure obtained in the standing and recumbent positions was expressed as percentage of the measure in the recumbent position, there was no significant association with gestational age (p=0.07). When all evaluations were considered, there was a significant association between cervical length in the recumbent and standing positions (r=0.79; p<0.001). The measures in recumbent and standing positions were inversely correlated with gestational age (recumbent: p<0.0001; standing: p<0.0001). The mean cervical length in the recumbent position was 33.5 mm (SD=10.8 mm) and 31.8 mm (SD=9.6 mm) in the standing position. There was no significant association between cervical length difference expressed as percentage of the measure in the recumbent position and gestation. Conclusion: cervical length measure obtained with the patients in the recumbent and standing positions provided similar information.

    See more
    Uterine Cervical Length Evaluation in the Standing and Recumbent Positions in Twin Pregnancies

Search

Search in:

Article type
abstract
book-review
brief-report
case-report -
correction
editorial
editorial -
letter
letter -
other -
rapid-communication
research-article
research-article -
review-article
review-article -
Section
Abstracts of Awarded Papers at the 50th Brazilian Congress of Gynecology and Obstetrics
Artigo de Revisão
Original Articles
Carta ao Editor
Case Report
Case Report and Treatment
Clinical Consensus Recommendation
Editorial
Editorial
Equipments and Methods
Erratum
Febrasgo Position Statement
Letter to the Editor
Methods and Techniques
Nota do Editor
Original Article
Original Article/Contraception
Original Article/Infertility
Original Article/Obstetrics
Original Article/Oncology
Original Article/Sexual Violence/Pediatric and Adolescent Gynecology
Original Article/Teaching and Training
Original Articles
Original Articles
Previous Note
Relato de Caso
Relatos de Casos
Resposta dos Autores
Resumo De Tese
Resumos de Teses
Review Article
Short Communication
Special Article
Systematic Review
Técnicas e Equipamentos
Thesis Abstract
Trabalhos Originais
Year / Volume
2024; v.46
2023; v.45
2022; v.44
2021; v.43
2020; v.42
2019; v.41
2018; v.40
2017; v.39
2016; v.38
2015; v.37
2014; v.36
2013; v.35
2012; v.34
2011; v.33
2010; v.32
2009; v.31
2008; v.30
2007; v.29
2006; v.28
2005; v.27
2004; v.26
2003; v.25
2002; v.24
2001; v.23
2000; v.22
1999; v.21
1998; v.20
ISSUE