Você pesquisou por y - Revista Brasileira de Ginecologia e Obstetrícia

You searched for:"Solange Sasaki"

We found (2) results for your search.
  • Trabalhos Originais

    Prevention of preterm birth: use of digital examination and transvaginal ultrasonography

    Revista Brasileira de Ginecologia e Obstetrícia. 1998;20(6):350-356

    Summary

    Trabalhos Originais

    Prevention of preterm birth: use of digital examination and transvaginal ultrasonography

    Revista Brasileira de Ginecologia e Obstetrícia. 1998;20(6):350-356

    DOI 10.1590/S0100-72031998000600008

    Views0

    Objective: to evaluate the uterine cervix by digital and transvaginal ultrasound examinations in pregnant women at high risk of having premature delivery. Methods: during the period between February 1995 and September 1997, 38 pregnant women at high risk of having premature delivery between the 20th and 36th week of gestation were examined. These patients were submitted weekly to both digital and transvaginal ultrasound examinations. The digital examination evaluated the uterine cervix using two parameters: length and dilation. The transvaginal ultrasound studied the length and the anteroposterior diameter of the uterine cervix. The behavior of these cervical measurements was analyzed throughout the pregnancies. The two methods were compared regarding cervical evaluation and accuracy of premature birth diagnosis. Results: the rate of premature deliveries was 18.4% (7/38). Digital examination resulted in cervical evaluations with variation coefficients of 30.3% for length and 193% for dilation. Transvaginal ultrasound resulted in cervical evaluations with variation coefficients of 14.7% and 26.5% for the anteroposterior diameter and length, respectively. The cervical length measures obtained on ultrasound were always greater than those obtained on digital examination. Through analysis with the hypothesis test, an indirect relationship was observed between the cervical length and the gestational period for digital examination and ultrasound study (p<0.05 and p<0.01, respectively), and a direct relationship between the cervical dilation and the gestational age observed on the digital examination (p<0.01). Conclusions: among the parameters studied by means of the digital and transvaginal ultrasound examinations, the ultrasound cervical length presented the best accuracy in the diagnosis of premature birth, proving to be more reliable for the evaluation of cervical alterations in pregnant women at high risk of premature delivery.

    See more
    Prevention of preterm birth: use of digital examination and transvaginal ultrasonography
  • Trabalhos Originais

    Arterial doppler velocimetry in pregnant women with previous idiopathic intrauterine growth retardation

    Revista Brasileira de Ginecologia e Obstetrícia. 1998;20(9):517-524

    Summary

    Trabalhos Originais

    Arterial doppler velocimetry in pregnant women with previous idiopathic intrauterine growth retardation

    Revista Brasileira de Ginecologia e Obstetrícia. 1998;20(9):517-524

    DOI 10.1590/S0100-72031998000900005

    Views0

    Purpose: to determine the behavior of doppler velocimetry during the course of risk pregnancies and to compare the perinatal results obtained for concepti with retarded intrauterine growth (RIUG) with those for concepti considered adequate for gestational age (AGA). Methods: a prospective study of the evolution of doppler ultrasound was made in 38 pregnant women with of idiopathic intrauterine growth retardation (IUGR) in previous pregnancy. A relationship was established between this antecedent and the new pregnancy. The pregnant women studied were divided into two groups in agreement with their neonates birthweight. Group 1 was associated with IUGR and group 2 with adequate birth weight. IUGR was confirmed in 23.7% of the cases. Umbilical and uterine artery doppler velocimetry was performed from 20 to 40 weeks of gestation. Middle cerebral artery doppler velocimetry was analyzed after 28 weeks of gestation, twice a month, being the last valued examination before birth. Results: the uterine and umbilical artery ratio at 24 and 28 weeks of gestation, respectively, correlated with the presence of IUGR. There was no difference between the two groups regarding the presence or absence of a small notch in the uterine artery wave form and middle cerebral artery doppler velocimetry ratio, at the last examination before birth. There was a relationship between neonatal stay in hospital for more than three days and the presence of IUGR. Conclusions: doppler ultrasound should be used in the follow-up of cases with a high risk of IUGR. It allows the detection of the fetuses at high risk of hypoxia and, by interrupting the pregnancy, fetal distress-related complications may be avoided.

    See more

Search

Search in:

Article type
abstract
book-review
brief-report
case-report
case-report -
correction
editorial
editorial -
letter
letter -
other
other -
rapid-communication
research-article
research-article -
review-article
review-article -
Section
Arigos Originais
Artigo de Revisão
Original Articles
Carta ao Editor
Carta ao Editor
Cartas
Case Report
Case Reports
Caso e Tratamento
Clinical Consensus Recommendation
Corrigendum
Editoriais
Editorial
Editorial
Equipamentos e Métodos
Errata
Erratas
Erratum
Febrasgo Position Statement
Febrasgo Statement
Febrasgo Statement Position
FIGO Statement
GUIDELINES
Integrative Review
Letter to Editor
Letter to Editor
Letter to the Editor
Letter to the Editor
Métodos e Técnicas
Nota do Editor
Nota Prévia
Original Article
Original Article/Contraception
Original Article/Infertility
Original Article/Obstetrics
Original Article/Oncology
Original Article/Sexual Violence/Pediatric and Adolescent Gynecology
Original Article/Teaching and Training
Original Articles
Original Articles
Relato de Caso
Relato de Casos
Relatos de Casos
Reply to the Letter to the Editor
Resposta dos Autores
Resumo De Tese
Resumo De Tese
Resumos de Tese
Resumos de Tese
Resumos de Teses
Resumos de Teses
Resumos dos Trabalhos Premiados no 50º Congresso Brasileiro de Ginecologia e Obstetrícia
Review
Review Article
Review Articles
Revisão
Revisão
Short Communication
Special Article
Systematic Review
Técnica e Equipamentos
Técnicas e Equipamentos
Técnicas e Métodos
Trabalhos Originais
Year / Volume
2024; v.46
2023; v.45
2022; v.44
2021; v.43
2020; v.42
2019; v.41
2018; v.40
2017; v.39
2016; v.38
2015; v.37
2014; v.36
2013; v.35
2012; v.34
2011; v.33
2010; v.32
2009; v.31
2008; v.30
2007; v.29
2006; v.28
2005; v.27
2004; v.26
2003; v.25
2002; v.24
2001; v.23
2000; v.22
1999; v.21
1998; v.20
ISSUE