Revista Brasileira de Ginecologia e Obstetrícia. 2019;41(8):476-484
Labor induction does not always result in vaginal delivery, and can expose both the mother and the fetus to the risks inherent to the induction procedure or a possible cesarean section. Transvaginal sonography (TVS) of the cervix is a useful tool to predict prematurity; in the present study, this tool was used to evaluate postterm induction.
We evaluated the ultrasound characteristics of the cervix (cervical length, cervical funneling, internal os dilation, the presence or absence of the cervical gland area [CGA], and the morphological changes of the cervix as a result of applying fundal pressure) before the onset of labor induction among women with postterm pregnancy to identify the possible predictors of failed labor induction. The Bishop score (BS) was used for comparison purposes. Three groups were evaluated: successful versus unsuccessful induction; vaginal delivery versus cesarean delivery (excluding cases of acute fetal distress [AFD]); and vaginal delivery versus cesarean delivery (including cases of AFD). A fourth group including only the primiparous women from the three previous groups was also evaluated.
Based on the studied characteristics and combinations of variables, a cervical length ≥ 3.0 cm and a BS ≤ 2 were the best predictors of induction failure.
Although TVS is useful for screening for induction failure, this tool should not be used as an indication for cesarean section.
Summary
Revista Brasileira de Ginecologia e Obstetrícia. 2006;28(8):460-466
DOI 10.1590/S0100-72032006000800004
PURPOSE: to assess the performance of lamellar body count compared to the shake (Clements) test in the prediction of fetal lung maturity in diabetics. METHODS: prospective study of 62 patients who underwent amniocentesis between the 26th and 39th week of pregnancy. Immediately after collection, the amniotic fluid sample was submitted to the shake test and lamellar body count. Deliveries occurred within three days of amniocentesis. Immature test results (absence of a complete bubble ring in the third tube for the shake test and less than 50,000 lamellar bodies) were confronted with the occurrence of pulmonary immaturity in the neonate (respiratory distress syndrome). The performance of both tests was compared using the chi2 test and p<0.05 was considered to be significant. RESULTS: seven infants had respiratory distress syndrome (11.3%). The lamellar body count and shake test were similar regarding sensitivity (100 vs 71.4%, respectively) and negative predictive value (100 vs 93.5%). Lamellar body count was superior as regards specificity (87.3 vs 52.7%, p=0.0001), positive predictive value (50 vs 16.1%, p=0.017), and accuracy (88.7 vs 54.8%, p<0.001). CONCLUSIONS: lamellar body count is a simple and accurate method of assessing fetal lung maturity. It performs slightly better than the shake test in terms of specificity, positive predictive value and accuracy, with the advantage of not requiring manipulation or reagents. Similar to the shake test, lamellar body count has a high-negative predictive value: mature results (50,000 or more) indicate thar the infant will not have hyaline membrane.