Você pesquisou por y - Revista Brasileira de Ginecologia e Obstetrícia

You searched for:"Francisco Mauad-Filho"

We found (4) results for your search.
  • Original Article

    Changes in amniotic fluid index estimated by ultrasonography in pregnant patients submitted to subtotal immersion in water

    Rev Bras Ginecol Obstet. 2001;23(2):101-105

    Summary

    Original Article

    Changes in amniotic fluid index estimated by ultrasonography in pregnant patients submitted to subtotal immersion in water

    Rev Bras Ginecol Obstet. 2001;23(2):101-105

    DOI 10.1590/S0100-72032001000200007

    Views2

    Purpose: to study the changes in amniotic fluid index (AFI) measured by ultrasonography, mean arterial pressure (MAP) and pulse rate in normal pregnant women submitted to subtotal body immersion in water for different periods of time, and to standardize the technique. Methods: AFI values were studied as recommended by Phelan et al.¹ in a group of 52 pregnant women with gestational age of 28 weeks or more considered to be clinically normal, before and after exposure to subtotal immersion in water heated to 32 to 34ºC for 30, 45 and 60 min. The patients were seen at the Ultrasonography and Medical Updating School of Ribeirão Preto and in the Department of Gynecology and Obstetrics of the Faculty of Medicine of Ribeirão Preto, University of São Paulo. Results: before and after immersion, the average of MAP was 87.8 and 87.1 in the group of 30 min, 76.7 and 66.6 in the group of 45 min and 77.4 and 60.7 in the group of 60 min, with statistical significance. Before and after immersion, the means of pulse rates were 74.9 and 78.7 in the group of 30 min, 83.6 and 85.2 in the group of 45 min and 84.9 and 90.6 in the group of 60 min, with statistical significance. The mean of AFI also showed statistical significance. When submitted to 30-min immersion the means of AFI were 11.7 cm before and 16.8 cm after. In the group of 45 min, the averages were 9.7 cm before and 13.8 cm after immersion. In the group of 60 min, the averages were 9.5 cm before and 13.6 cm after immersion. The time of immersion of 30-min was as effective and ample as 45 or 60 min. Conclusions: subtotal immersion in water is a safe and practical procedure that can mobilize fluids during pregnancy, increasing amniotic fluid volume.

    See more
    Changes in amniotic fluid index estimated by ultrasonography in pregnant patients submitted to subtotal immersion in water
  • Original Article

    Changes in cervical length during pregnancy measured by transvaginal ultrasound

    Rev Bras Ginecol Obstet. 2003;25(2):115-121

    Summary

    Original Article

    Changes in cervical length during pregnancy measured by transvaginal ultrasound

    Rev Bras Ginecol Obstet. 2003;25(2):115-121

    DOI 10.1590/S0100-72032003000200007

    Views17

    PURPOSE: to establish a normality curve of cervical length during pregnancy measured by transvaginal ultrasonography. METHODS: we conducted a prospective, longitudinal study on 82 healthy pregnant women who were followed up from the beginning of pregnancy to delivery at four-week intervals, of whom 49 concluded the study. Patients were divided according to parity into nulliparous women and women with one or more previous deliveries. Cervical length was measured in a sagittal view by transvaginal ultrasonography, as the linear distance between internal and external cervical os. RESULTS: no significant difference was observed in mean cervical length or the 5th, 25, 50th, 75th, or 95th percentile according to gestational age between groups (p>0.05). Between the 20thand 24th gestacional week, the 5th, 50th and 95th percentiles of cervical length were 28, 35 and 47.2 mm, respectively. Cervical length decreased progressively during normal pregnancy, with a significant shortening observed after 20 weeks of gestation and being more marked after 28 weeks (p<0.05). CONCLUSION: the pattern of cervical length behavior does not seem to differ between nulliparous women and women with one or more previous deliveries. The numerical values of the normality curve of cervical length according to gestational age reflect the variability in the peculiar characteristics of the studied sample, thus emphasizing the value of the parameters established for different populations.

    See more
    Changes in cervical length during pregnancy measured by transvaginal ultrasound
  • Original Article

    Peak expiratory flow analysis in healthy pregnant women

    Rev Bras Ginecol Obstet. 2005;27(1):37-43

    Summary

    Original Article

    Peak expiratory flow analysis in healthy pregnant women

    Rev Bras Ginecol Obstet. 2005;27(1):37-43

    DOI 10.1590/S0100-72032005000100008

    Views2

    PURPOSE: to investigate the normal peak expiratory flow values in healthy pregnant women employing a portable expiratory apparatus (Mini-Wright Peak Flow Meter), and to relate the obtained measurements to each patient's height, body mass index (BMI) and age, along gestation. METHODS: a longitudinal prospective study including 26 pregnant women followed up from the first trimester to the 36th week of gestation and examined every four weeks. On the occasion of seven visits, the pregnant women performed forced exhaling into a portable expiratory apparatus three times, with the highest value being considered the peak expiratory flow. All measurements were made under the same investigator's supervision in order to reduce the margin of error. Pearson coefficient was used to calculate the correlation between flow and BMI, between flow and patient's height, and between flow and patient's age. RESULTS: the variation in flow values during pregnancy can be determined by flow = 328.32 -0.07 x week, with a Pearson coefficient equal to zero. To determine whether there was a difference in the correlation coefficients between BMI and flow, we compared the lowest coefficient (0.47 for week 30, flow = 123.49 + 7.64 x BMI) with the highest coefficient (0.59 for week 34, flow = 87.77 + 9.05 x BMI) of each studied time interval and obtained a value of 0.22, indicating a good correlation between the flow and BMI variables. There was a positive correlation between height and flow (Pearson = 0.61), with flow = -477.47 + 497.38 x height. The correlation coefficient between flow and age was 0.24, with the equation obtained in this case being non-linear. CONCLUSIONS: peak expiratory flow values did not change along gestation. Higher flows were observed in taller women. Pregnant women with a higher BMI before gestation presented higher flows. There was no correlation between flow and maternal age.

    See more
    Peak expiratory flow analysis in healthy pregnant women
  • Original Article

    Materno-fetal hemodynamic repercussion of glucose ingestion

    Rev Bras Ginecol Obstet. 2006;28(12):693-699

    Summary

    Original Article

    Materno-fetal hemodynamic repercussion of glucose ingestion

    Rev Bras Ginecol Obstet. 2006;28(12):693-699

    DOI 10.1590/S0100-72032006001200002

    Views2

    PURPOSE: to analyze the effect of glucose in the materno-fetal hemodynamics through dopplervelocimetric assessment of the materno-fetal and fetoplacentary circulation. METHODS: the study was carried out by a single observer on 31 clinically healthy pregnant women from the 28th to the 36th gestational week. Parameters were assessed immediately before or 60 minutes after the ingestion of 50 g of glucose. The including criteria comprised normal clinical and laboratorial evaluation, the presence of only one fetus, gestational age between 28 and 36 weeks confirmed by ultrasonography and/or the date of the last menstruation, fasting glycemia less or equal to 110 mg/dL and less than 140 mg/dL after 50 g of glucose overload. The excluding criteria consisted of the presence of fetal malformation or development alterations, labor, diabetes as a family predisposition, pathologies due to or underlying gestation and use of tobacco, alcohol and/or other substances. The mother´s common carotid artery and uterine arteries, the umbilical artery and the fetal medial cerebral artery and abdominal aorta were evaluated. In each blood vessel, the following parameters were analyzed: resistance index, pulsatility index, maximum systolic speed, final diastolic speed and acceleration time. The fetal heart rate was evaluated by M Mode ultrasonography. For the statistical analysis, the Student's t test was used when the variable presented normal distribution in Kolmogorov-Smirnov's test. When normality was rejected, the Wilcoxon's non-parametric test was used, with the significance level always established at p<0.05. RESULTS: the maternal glycemia increased after the ingestion of 50 g of glucose (before: 68.0±10.1 mg/dL and after: 104.6±28.2 mg/dL; p<0.001), and fetal heart rate decreased after the glucose ingestion (before: 137.9±6.1 bpm and after: 134.5±6.9 bpm; p<0.001). The umbilical artery presented an increase in the pulsatility index (before: 0.8±0.1 and after: 0.9±0.2; p=0.03). Significant velocimetric alterations were not found in the other vessels or in the other indexes investigated. CONCLUSIONS: in spite of the variation in the levels of maternal glycemia and in the fetal heart rate following glucose ingestion, no significant flow alteration occurred in the following vessels: umbilical artery, fetal medial cerebral artery and aorta; nor in the carotid and uterine maternal arteries. We conclude that the glucose concentration used was released without hemodynamic interference in the materno-fetal compartment.

    See more

Search

Search in:

Article type
abstract
book-review
brief-report
case-report -
correction
editorial
editorial -
letter
letter -
other -
rapid-communication
research-article
research-article -
review-article
review-article -
Section
Abstracts of Awarded Papers at the 50th Brazilian Congress of Gynecology and Obstetrics
Artigo de Revisão
Original Articles
Carta ao Editor
Case Report
Case Report and Treatment
Clinical Consensus Recommendation
Editorial
Editorial
Equipments and Methods
Erratum
Febrasgo Position Statement
Letter to the Editor
Methods and Techniques
Nota do Editor
Original Article
Original Article/Contraception
Original Article/Infertility
Original Article/Obstetrics
Original Article/Oncology
Original Article/Sexual Violence/Pediatric and Adolescent Gynecology
Original Article/Teaching and Training
Original Articles
Original Articles
Previous Note
Relato de Caso
Relatos de Casos
Resposta dos Autores
Resumo De Tese
Resumos de Teses
Review Article
Short Communication
Special Article
Systematic Review
Técnicas e Equipamentos
Thesis Abstract
Trabalhos Originais
Year / Volume
2024; v.46
2023; v.45
2022; v.44
2021; v.43
2020; v.42
2019; v.41
2018; v.40
2017; v.39
2016; v.38
2015; v.37
2014; v.36
2013; v.35
2012; v.34
2011; v.33
2010; v.32
2009; v.31
2008; v.30
2007; v.29
2006; v.28
2005; v.27
2004; v.26
2003; v.25
2002; v.24
2001; v.23
2000; v.22
1999; v.21
1998; v.20
ISSUE