Você pesquisou por y - Revista Brasileira de Ginecologia e Obstetrícia

You searched for:"Emerson Oliveira"

We found (8) results for your search.
  • Original Article

    WhatsApp and Gynecologist-Patient Interaction: Development and Validation of a Questionnaire to Assess the Stress Perceived by the Doctor

    Revista Brasileira de Ginecologia e Obstetrícia. 2022;44(5):497-502

    Summary

    Original Article

    WhatsApp and Gynecologist-Patient Interaction: Development and Validation of a Questionnaire to Assess the Stress Perceived by the Doctor

    Revista Brasileira de Ginecologia e Obstetrícia. 2022;44(5):497-502

    DOI 10.1055/s-0042-1744289

    Views5

    Abstract

    Objective

    Construction and validation of the WhatsApp Stress Scale (WASS), a questionnaire designed for physicians that measures how the use of smartphones and related software communication applications affects the quality of life of gynecologists who use this tool to communicate with patients.

    Methods

    The present cross-sectional observational study analyzed 60 gynecologists according to weekly WhatsApp usage time for communication with patients and compared the data with the perception of the doctor on the use of this virtual interaction as a stressor. Physicians were equally divided into three groups:<2hours, 2 to 5 hours, and>5 hours. The authors created a questionnaire in Likert scale format. The study proceeded in three phases: development of the questionnaire items, pretesting, constructing, and validity and reliability testing using factor analysis, Cronbach α coefficient, and paired t-test.

    Results

    A 9-item instrument using a 5-point Likert scale was created and administered to the participants in 3 different times: T0, T1 (15minutes after the end of T0), and T2 (15 days later). All questionnaire items possessed adequate content validity indices and the internal consistency of the instrument was satisfactory (Cronbach α 0.935; 95% confidence interval [CI]: 0.744-0.989; p=0.0001). No statistically significant differences were observed in the responses between the rounds of testing, indicating good test-retest reliability. A positive association between the high frequency of WhatsApp usage for communication with patients and the stress perceived by the doctor was shown.

    Conclusion

    The WASS is a valid and reliable instrument for assessing the use of messaging applications to communicate with patients as a stressor perceived by gynecologists.

    See more
  • Original Articles

    Ultrasound Evaluation of the Cervix to Predict Failed Labor Induction

    Revista Brasileira de Ginecologia e Obstetrícia. 2019;41(8):476-484

    Summary

    Original Articles

    Ultrasound Evaluation of the Cervix to Predict Failed Labor Induction

    Revista Brasileira de Ginecologia e Obstetrícia. 2019;41(8):476-484

    DOI 10.1055/s-0039-1693679

    Views19

    Abstract

    Objective

    Labor induction does not always result in vaginal delivery, and can expose both the mother and the fetus to the risks inherent to the induction procedure or a possible cesarean section. Transvaginal sonography (TVS) of the cervix is a useful tool to predict prematurity; in the present study, this tool was used to evaluate postterm induction.

    Methods

    We evaluated the ultrasound characteristics of the cervix (cervical length, cervical funneling, internal os dilation, the presence or absence of the cervical gland area [CGA], and the morphological changes of the cervix as a result of applying fundal pressure) before the onset of labor induction among women with postterm pregnancy to identify the possible predictors of failed labor induction. The Bishop score (BS) was used for comparison purposes. Three groups were evaluated: successful versus unsuccessful induction; vaginal delivery versus cesarean delivery (excluding cases of acute fetal distress [AFD]); and vaginal delivery versus cesarean delivery (including cases of AFD). A fourth group including only the primiparous women from the three previous groups was also evaluated.

    Results

    Based on the studied characteristics and combinations of variables, a cervical length ≥ 3.0 cm and a BS ≤ 2 were the best predictors of induction failure.

    Conclusion

    Although TVS is useful for screening for induction failure, this tool should not be used as an indication for cesarean section.

    See more
  • Original Article

    Assessment of Metalloproteinase Matrix 9 (MMP9) Gene Polymorphisms Risk Factors for Pelvic Organ Prolapse in the Brazilian Population

    Revista Brasileira de Ginecologia e Obstetrícia. 2019;41(3):164-169

    Summary

    Original Article

    Assessment of Metalloproteinase Matrix 9 (MMP9) Gene Polymorphisms Risk Factors for Pelvic Organ Prolapse in the Brazilian Population

    Revista Brasileira de Ginecologia e Obstetrícia. 2019;41(3):164-169

    DOI 10.1055/s-0039-1681112

    Views7

    Abstract

    Objective

    To evaluate the C-1562T matrix metalloproteinase 9 (MMP9) gene polymorphisms as risk factors related to the occurrence of pelvic organ prolapse (POP) and to identifytheclinicalvariablesassociatedwith theoccurrenceof thedisease.Epidemiological studies of risk factors for POP do not explain why nulliparous women with no known risk factors also develop POP. Therefore, genetic factors may be involved.

    Methods

    Cohort study with 86 women with symptomatic POP (cases), and 158 women withoutapriororcurrentdiagnosisof thisdisorder(controls).Thegroupswereanalyzedfor the presence of MMP9 gene polymorphisms. Genotyping was performed using polymerase chainreaction(PCR)with DNA obtained froma peripheral venouspuncture ofboth groups.

    Results

    There were no differences between the cases and controls even when we grouped the mutant homozygous and heterozygous genotypes. The analysis of patients with a complete absence of POP versus patients with total POP also showed no statistically significant differences. Ageand home birth were found to be independent risk factors for POP.

    Conclusions

    There were no statistically significant differences in the C-1562T MMP9 polymorphisms between the cases and controls in Brazilian women.

    See more
    Assessment of Metalloproteinase Matrix 9 (MMP9) Gene Polymorphisms Risk Factors for Pelvic Organ Prolapse in the Brazilian Population
  • Original Articles

    The Influence of CYP3A4 Polymorphism in Sex Steroids as a Risk Factor for Breast Cancer

    Revista Brasileira de Ginecologia e Obstetrícia. 2018;40(11):699-704

    Summary

    Original Articles

    The Influence of CYP3A4 Polymorphism in Sex Steroids as a Risk Factor for Breast Cancer

    Revista Brasileira de Ginecologia e Obstetrícia. 2018;40(11):699-704

    DOI 10.1055/s-0038-1673365

    Views8

    Abstract

    Objective

    Epidemiological studies have shown evidence of the effect of sex hormones in the pathogenesis of breast cancer, and have suggested a relationship of the disease with variations in genes involved in estrogen synthesis and/or metabolism. The aim of the present study was to evaluate the association between the CYP3A4*1B gene polymorphism (rs2740574) and the risk of developing breast cancer.

    Methods

    In the present case-control study, the frequency of the CYP3A4*1B gene polymorphism was determined in 148 women with breast cancer and in 245 women without the disease. The DNA of the participants was extracted from plasma samples, and the gene was amplified by polymerase chain reaction. The presence of the polymorphism was determined using restriction enzymes.

    Results

    After adjusting for confounding variables, we have found that the polymorphism was not associated with the occurrence of breast cancer (odds ratio = 1.151; 95% confidence interval: 0.714–1.856; p= 0.564). We have also found no association with the presence of hormone receptors, with human epidermal growth factor receptor 2 (HER2) overexpression, or with the rate of tumor cell proliferation.

    Conclusion

    We have not observed a relationship between the CYP3A4*1B gene polymorphism and the occurrence of breast cancer.

    See more
    The Influence of CYP3A4 Polymorphism in Sex Steroids as a Risk Factor for Breast Cancer
  • Original Article

    Association between Matrix Metallopeptidase 9 Polymorphism and Breast Cancer Risk

    Revista Brasileira de Ginecologia e Obstetrícia. 2018;40(10):620-624

    Summary

    Original Article

    Association between Matrix Metallopeptidase 9 Polymorphism and Breast Cancer Risk

    Revista Brasileira de Ginecologia e Obstetrícia. 2018;40(10):620-624

    DOI 10.1055/s-0038-1673366

    Views0

    Abstract

    Objective

    Epidemiological studies have shown evidence of the effect of genetic variations in the pathogenesis of breast cancer and have suggested a relationship of the disease with genetic polymorphisms. Matrix metallopeptidase 9 (MMP-9) is a collagenase responsible for the degradation of type IV collagen, the major component of the basement membrane, and other essential extra cellular matrix components, being involved in the tumor cell invasion and metastasis. Our objective was to evaluate the relationship between the MMP-9-1562 C/T polymorphism (rs 3918242) and the risk of developing breast cancer.

    Methods

    In this case-control study, the frequency of the MMP-9-1562 C/T polymorphism (rs 3918242) was determined in 148 women with breast cancer and 245 women without the disease. The DNA was extracted from plasma samples, and the gene was amplified by polymerase chain reaction (PCR); the presence of the polymorphism was determined using restriction enzymes.

    Results

    After adjusting for confounding variables, we found that the polymorphism was not associated with the occurrence of breast cancer (odds ratio [OR] = 1.159, 95% confidence interval [CI]: 0.6625-1.997, p = 0.5964). We also found no association with more advanced disease, the presence of hormone receptors, human epidermal growth factor receptor 2 (HER2) overexpression, or rate of tumor cell proliferation.

    Conclusion

    We did not observe a relationship between MMP-9-1562 C/T polymorphism (rs 3918242) and the occurrence of breast cancer.

    See more
  • Artigos Originais

    Body mass index influence in female urinary incontinence

    Revista Brasileira de Ginecologia e Obstetrícia. 2010;32(9):454-458

    Summary

    Artigos Originais

    Body mass index influence in female urinary incontinence

    Revista Brasileira de Ginecologia e Obstetrícia. 2010;32(9):454-458

    DOI 10.1590/S0100-72032010000900007

    Views1

    PURPOSE: to evaluate and compare the effects of body mass index (BMI) on the severity of female urinary incontinence (UI) using the quality of life questionnaire King's Health Questionnaire (KHQ), variables of urodynamic studies and the medical history taken. METHODS: cross-sectional clinical study. We selected 65 patients with stress urinary incontinence (SUI) who were divided into three groups: Group I (BMI: 18-25 kg/m²), Group II (BMI: 25-30 kg/m²) and Group III (BMI>30 kg/m²). The KHQ domains were compared between these groups. In addition, some clinical history urodynamic data (presence of nocturia, enuresis, urgency and urge incontinence) were also related to BMI by calculating the Odds Ratio (OR). The BMI in the presence and absence of non-inhibited detrusor contractions and Valsalva leak point pressure (VLPP) <60 or > 60 cmH2O were evaluated. Finally, the correlation between BMI and the nine KHQ domains has been tested in order to detect some association. RESULTS: the KHQ did not record deterioration of quality of life in women with UI with increasing BMI in any of its areas. The OR for the presence of enuresis in relation to a BMI was 1.003 [CI: 0.897-1.121], p=0.962. The OR for nocturia was 1.049 [CI: 0.933-1.18], p=.425. The OR for urgency was 0.975 [CI: 0.826-1.151], p=0.762, and the OR for incontinence was 0.978 [CI: 0.85-1.126], p=0.76. We studied the BMI in patients with and without non-inhibited detrusor contractions and detected medians of 26.4±4.8 and 28.3±5.7 kg/m², respectively (p=0.6). Similarly, the median BMI values for the groups with VLPP <60 and >60 cmH2O were 29.6±4.1 and 27.7±5.7 kg/m², respectively (p=0.2). Finally, we failed to demonstrate an association between BMI and any of the nine KHQ domains by means of the Spearman correlation. CONCLUSION: there was no association of KHQ scores with BMI. There was also no correlation between the parameters of clinical history and of the urodynamic study with BMI.

    See more
  • Artigos Originais

    Electrical stimulation of the pelvic floor versus vaginal cone therapy for the treatment of stress urinary incontinence

    Revista Brasileira de Ginecologia e Obstetrícia. 2009;31(9):447-452

    Summary

    Artigos Originais

    Electrical stimulation of the pelvic floor versus vaginal cone therapy for the treatment of stress urinary incontinence

    Revista Brasileira de Ginecologia e Obstetrícia. 2009;31(9):447-452

    DOI 10.1590/S0100-72032009000900005

    Views0

    PURPOSE: to compare the effects of functional electrostimulation of the pelvic floor and therapy with cones in women with stress urinary incontinence (SUI). METHODS: randomized clinical study for which 45 patients with SUI were selected. The effects of functional electrostimulation of the pelvic floor were evaluated in the SUI treatment of 24 women, with the use of clinical data (micturition diary, pad test and a questionnaire about quality of life - I-QoL). The patients were submitted to two 20' weekly sessions for four consecutive months, under the supervision of a physiotherapist. The electrode used had 10 cm length and 3.5 cm width with a double metallic ring and a cylindrical shape, positioned in the medium third of the vagina. The electric parameters used were: intensity varying from 10 to 100 mA and 50 Hz of fixed frequency, with pulse duration of 1 ms. Also, we evaluated 21 patients who were submitted to vaginal cone treatment. The cone therapy was done with two 45 minute sessions per week. The cones' weight varied from 20 to 100 gr. RESULTS: there was no difference between the outcomes of electrostimulation of the pelvic floor and the vaginal cones for the treatment of SUI (p>0.05). After four months, there was a significant improvement in the I-QoL index of the patients treated both with electrostimulation (40.3 versus 82.9) or with the cones (47.7 versus 84.1). There was a significant decrease in pad weight in both groups, measured before and after the treatment (28.5 and 32 g versus 2.0 and 3.0 g for the electrostimulation and cone group, respectively). Finally, there was a significant decrease in the number of urinary leakage evaluated by the micturition diary in both groups (p<0.0001). CONCLUSIONS: both electrostimulation and vaginal cones were effective in the treatment of women with SUI.

    See more
  • Trabalhos Originais

    Interobserver reproducibility of pelvic organ prolapse classification suggested by the International Continence Society

    Revista Brasileira de Ginecologia e Obstetrícia. 2003;25(5):353-358

    Summary

    Trabalhos Originais

    Interobserver reproducibility of pelvic organ prolapse classification suggested by the International Continence Society

    Revista Brasileira de Ginecologia e Obstetrícia. 2003;25(5):353-358

    DOI 10.1590/S0100-72032003000500008

    Views1

    PURPOSE: to determine interobserver reliability of site-specific measurements and stages according to the proposed International Continence Society prolapse terminology document. METHODS: we analyzed 51 women during urogynecological investigation performed at the Urogynecology and Vaginal Surgery Sector of UNIFESP / EPM. We recorded the locations of point-specific measures proposed by the International Continence Society (ICS). They are: two in the anterior vaginal wall, two in the superior vagina, two in the posterior vaginal wall, genital hiatus, perineal body and total vaginal length. Then we recorded the stage of genital prolapse. Women underwent pelvic examinations by two investigators, each blinded to the results of the other's examination. The reproducibility of the nine site-specific measurements and the summary stage were analyzed using Pearson's correlation coefficient and the median measurements were compared by the paired-t test. RESULTS: there were substantial and highly significant correlations for each of the nine measurements. Correlation coefficient for point Aa was 0.89 (p<0.0001), point Ba 0.90 (p<0.0001), point C 0.97 (p<0.0001), point Ap de 0.72 (p<0.0001), point Bp 0.84 (p<0.0001), point D 0.91 (p<0.0001), genital hiatus 0.65 (p<0.0001), perineal body 0.66 (p<0.0001) e total vaginal length 0.73 (p<0.0001). We also did not note differences between the means of measurements by the two examiners. Staging was highly reproducible (r=0.81, p<0.0001). ln no subject did the stage vary by more than one; in 86,2%, stages were identical. CONCLUSIONS: there is a good reproducibility of measures using the system proposed by the International Continence Society prolapse terminology document.

    See more
    Interobserver reproducibility of pelvic organ prolapse classification suggested by the International Continence Society

Search

Search in:

Article type
abstract
book-review
brief-report
case-report
case-report -
correction
editorial
editorial -
letter
letter -
other
other -
rapid-communication
research-article
research-article -
review-article
review-article -
Section
Arigos Originais
Artigo de Revisão
Original Articles
Carta ao Editor
Carta ao Editor
Cartas
Case Report
Case Reports
Caso e Tratamento
Clinical Consensus Recommendation
Corrigendum
Editoriais
Editorial
Editorial
Equipamentos e Métodos
Errata
Erratas
Erratum
Febrasgo Position Statement
Febrasgo Statement
Febrasgo Statement Position
FIGO Statement
GUIDELINES
Integrative Review
Letter to Editor
Letter to Editor
Letter to the Editor
Letter to the Editor
Métodos e Técnicas
Nota do Editor
Nota Prévia
Original Article
Original Article/Contraception
Original Article/Infertility
Original Article/Obstetrics
Original Article/Oncology
Original Article/Sexual Violence/Pediatric and Adolescent Gynecology
Original Article/Teaching and Training
Original Articles
Original Articles
Relato de Caso
Relato de Casos
Relatos de Casos
Reply to the Letter to the Editor
Resposta dos Autores
Resumo De Tese
Resumo De Tese
Resumos de Tese
Resumos de Tese
Resumos de Teses
Resumos de Teses
Resumos dos Trabalhos Premiados no 50º Congresso Brasileiro de Ginecologia e Obstetrícia
Review
Review Article
Review Articles
Revisão
Revisão
Short Communication
Special Article
Systematic Review
Técnica e Equipamentos
Técnicas e Equipamentos
Técnicas e Métodos
Trabalhos Originais
Year / Volume
2024; v.46
2023; v.45
2022; v.44
2021; v.43
2020; v.42
2019; v.41
2018; v.40
2017; v.39
2016; v.38
2015; v.37
2014; v.36
2013; v.35
2012; v.34
2011; v.33
2010; v.32
2009; v.31
2008; v.30
2007; v.29
2006; v.28
2005; v.27
2004; v.26
2003; v.25
2002; v.24
2001; v.23
2000; v.22
1999; v.21
1998; v.20
ISSUE