Você pesquisou por y - Revista Brasileira de Ginecologia e Obstetrícia

You searched for:"Bernardo L. Spiro"

We found (1) results for your search.
  • Original Article

    Sentinel lymph node detection in breast cancer: comparison between methods

    Rev Bras Ginecol Obstet. 2002;24(7):479-484

    Summary

    Original Article

    Sentinel lymph node detection in breast cancer: comparison between methods

    Rev Bras Ginecol Obstet. 2002;24(7):479-484

    DOI 10.1590/S0100-72032002000700008

    Views1

    Purpose: to evaluate the lymphoscintigraphy, the hand-held probe and the vital blue dye to identify the sentinel lymph node (SLN) in breast carcinoma and to establish sensitivity, negative predictive value (NPV) and overall accuracy of the SLN detection. Methods: eighty-eight consecutive attended patients, with clinically negative axillary lymph nodes were enrolled for this study using the technique of mapping with 99m technetium dextran for scintigraphic images before surgery. In the operating room, five minutes before axillary incision, we injected 2 mL of 2.5% Bleu Patente V Sodique around the tumor and intradermally. Then the gamma probe helped to find out the hot spot where the SLN was supposed to be. The pathologic results of SLN were obtained by the standard technique with hematoxylin and eosin staining in seventy-seven patients. Results: scintigraphy was conclusive for lymphatic basins in 62.1% of 58 cases, concerning SLN identification. In these conclusive patients, there were 9 in which 2 nodes appeared simultaneously without lymph vessel delineation. Using the gamma probe, at least one axillary SLN site could be found preoperatively in 45 cases (84.9%), and intraoperatively, associated with blue dye, in all 53 patients. In 32 of 35 patients only vital blue dye was used with success. Concerning the groups "day" and "other day" (when biopsy was performed on the same day or the other day, after the radiolabeled injection), therefore different regarding time and gamma counts, both achieved the same results regarding SLN detection. Forty-one patients had positive axillary lymph nodes and only two had false negative SLN, giving sensitivity of 95.3%, a NPV of 95.5% and overall accuracy of 97.7%. Conclusions: the lymph node mapping with the use of technetium and patent blue V, alone or associated, is feasible. The time since the injection of technetium up to surgery varied from 3 to 17 h. The pathologic findings confirmed that the biopsied lymph node was the true sentinel node in 97.6% of the cases and validated the SLN mapping, and this should lead to an avoidance of complete axillary dissection as a routine procedure in patients with negative SLN.

    See more

Search

Search in:

Article type
abstract
book-review
brief-report
case-report -
correction
editorial
editorial -
letter
letter -
other -
rapid-communication
research-article
research-article -
review-article
review-article -
Section
Abstracts of Awarded Papers at the 50th Brazilian Congress of Gynecology and Obstetrics
Artigo de Revisão
Original Articles
Carta ao Editor
Case Report
Case Report and Treatment
Clinical Consensus Recommendation
Editorial
Editorial
Equipments and Methods
Erratum
Febrasgo Position Statement
Letter to the Editor
Methods and Techniques
Nota do Editor
Original Article
Original Article/Contraception
Original Article/Infertility
Original Article/Obstetrics
Original Article/Oncology
Original Article/Sexual Violence/Pediatric and Adolescent Gynecology
Original Article/Teaching and Training
Original Articles
Original Articles
Previous Note
Relato de Caso
Relatos de Casos
Resposta dos Autores
Resumo De Tese
Resumos de Teses
Review Article
Short Communication
Special Article
Systematic Review
Técnicas e Equipamentos
Thesis Abstract
Trabalhos Originais
Year / Volume
2024; v.46
2023; v.45
2022; v.44
2021; v.43
2020; v.42
2019; v.41
2018; v.40
2017; v.39
2016; v.38
2015; v.37
2014; v.36
2013; v.35
2012; v.34
2011; v.33
2010; v.32
2009; v.31
2008; v.30
2007; v.29
2006; v.28
2005; v.27
2004; v.26
2003; v.25
2002; v.24
2001; v.23
2000; v.22
1999; v.21
1998; v.20
ISSUE