Você pesquisou por y - Revista Brasileira de Ginecologia e Obstetrícia

You searched for:"Barbara Zantut Wittmann"

We found (1) results for your search.
  • Original Article

    Consecutive Use of the 52 mg Levonorgestrel-releasing Intrauterine System: Variations in Bleeding Patterns

    Revista Brasileira de Ginecologia e Obstetrícia. 2020;42(4):194-199

    Summary

    Original Article

    Consecutive Use of the 52 mg Levonorgestrel-releasing Intrauterine System: Variations in Bleeding Patterns

    Revista Brasileira de Ginecologia e Obstetrícia. 2020;42(4):194-199

    DOI 10.1055/s-0040-1708092

    Views3

    Abstract

    Objective

    Changes in bleeding patterns could influence the decisions of healthcare professionals to change the levonorgestrel-releasing intrauterine system (LNG-IUS) before 7 years of use, the recommended period of extended use. We evaluated changes in the bleeding patterns of users of the 52 mg LNG-IUS at the end of use of the first (IUS-1) and during the second device (IUS-2) use.

    Methods

    We performed an audit of the medical records of all women who used two consecutive LNG-IUSs at the Family Planning clinic. We evaluated the sociodemographic/gynecological variables, the length of use, and the bleeding patterns reported in the reference periods of 90 days before removal of the IUS-1 and at the last return in use of IUS-2. We used the McNemar test to compare bleeding patterns. Statistical significance was established at p < 0.05.

    Results

    We evaluated 301 women aged (mean ± SD) 32 (±6.1) years, with lengths of use of 68.9 (±16.8) and 20.3 (±16.7) months for the IUS-1 and IUS-2, respectively. No pregnancies were reported. Bleeding patterns varied significantly among women who used the IUS-2 for ≥ 7 months to 6 years when compared the bleeding patterns reported in IUS-1 use. Eighty-nine out of 221 (40%) women maintained amenorrhea and infrequent bleeding; 66 (30%) evolved to bleeding patterns with light flow, and 66 (30%) maintained or evolved to heavy flow patterns (p = 0.012). No differences were observed among the 80 women with ≤ 6 months of use.

    Conclusion

    Changes in bleeding patterns occur during the use of LNG-IUS and should not be decisive for the early replacement of the device.

    See more

Search

Search in:

Article type
abstract
book-review
brief-report
case-report
case-report -
correction
editorial
editorial -
letter
letter -
other
other -
rapid-communication
research-article
research-article -
review-article
review-article -
Section
Arigos Originais
Artigo de Revisão
Original Articles
Carta ao Editor
Carta ao Editor
Cartas
Case Report
Case Reports
Caso e Tratamento
Clinical Consensus Recommendation
Corrigendum
Editoriais
Editorial
Editorial
Equipamentos e Métodos
Errata
Erratas
Erratum
Febrasgo Position Statement
Febrasgo Statement
Febrasgo Statement Position
FIGO Statement
GUIDELINES
Integrative Review
Letter to Editor
Letter to Editor
Letter to the Editor
Letter to the Editor
Métodos e Técnicas
Nota do Editor
Nota Prévia
Original Article
Original Article/Contraception
Original Article/Infertility
Original Article/Obstetrics
Original Article/Oncology
Original Article/Sexual Violence/Pediatric and Adolescent Gynecology
Original Article/Teaching and Training
Original Articles
Original Articles
Relato de Caso
Relato de Casos
Relatos de Casos
Reply to the Letter to the Editor
Resposta dos Autores
Resumo De Tese
Resumo De Tese
Resumos de Tese
Resumos de Tese
Resumos de Teses
Resumos de Teses
Resumos dos Trabalhos Premiados no 50º Congresso Brasileiro de Ginecologia e Obstetrícia
Review
Review Article
Review Articles
Revisão
Revisão
Short Communication
Special Article
Systematic Review
Técnica e Equipamentos
Técnicas e Equipamentos
Técnicas e Métodos
Trabalhos Originais
Year / Volume
2024; v.46
2023; v.45
2022; v.44
2021; v.43
2020; v.42
2019; v.41
2018; v.40
2017; v.39
2016; v.38
2015; v.37
2014; v.36
2013; v.35
2012; v.34
2011; v.33
2010; v.32
2009; v.31
2008; v.30
2007; v.29
2006; v.28
2005; v.27
2004; v.26
2003; v.25
2002; v.24
2001; v.23
2000; v.22
1999; v.21
1998; v.20
ISSUE