Summary
Revista Brasileira de Ginecologia e Obstetrícia. 2004;26(5):347-347
Summary
Revista Brasileira de Ginecologia e Obstetrícia. 2004;26(5):349-354
DOI 10.1590/S0100-72032004000500002
OBJECTIVE: to evaluate the accuracy of both the transverse diameter of the cerebellum (TDC) and of the transverse diameter/abdominal circumference (TDC/AC) ratio in the detection of fetal growth restriction (FGR), in high-risk pregnancies. METHOD: a prospective cross-sectional study was carried out in 260 patients with gestational age between 28 and 40 weeks. The TDC and AC of fetuses were measured through ultrasound and the fetuses with TDC below the 10th percentile or TDC/AC ratio above the 90th percentile (>14.6) were classified as FGR suspects. After birth, the accuracy of the TDC and TDC/AC was evaluated using the neonatal diagnosis of FGR as the gold standard (birth weight <10th percentile). RESULTS: after birth, 79 newborns (30.4%) were classified as small for gestational age. The TDC was appropriate in 74 (93.7%) of these fetuses and small in only 5 (6.3%). The sensitivity (SE), specificity (SP), positive (PPV) and negative (NPV) predictive values and accuracy of the TDC in the prediction of FGR were 6.3, 93.4, 29.4, 69.5, and 67%, respectively. The TDC/AC >14.6 correctly identified 59 of the 79 growth-restricted fetuses, with 27 false-positives and 20 false-negatives, SE of 74.5%, SP of 85.1%, PPV of 68.6%, NPV of 88.5% and 81.9% accuracy. CONCLUSION: the TDC is not a good screening parameter for the detection of FGR while the TDC/AC ratio above the 90th percentile is effective in this detection.
Summary
Revista Brasileira de Ginecologia e Obstetrícia. 2004;26(5):355-361
DOI 10.1590/S0100-72032004000500003
OBJECTIVE: to assess through Dopllerfluxometry the S/A ratio of the ductus venosus and determine the cut-off point to identify preterm fetuses with the 'brain sparing phenomenon". METHOD: a cross-sectional study was performed in 60 pregnant women that presented the "brain sparing phenomenon" (umbilical cerebral ratio >1) and gestational age between 25 and 33 weeks. The following parameters were studied: S/A ratio of the ductus venosus, pH and base excess (BE) of a fetal blood sample collected from the umbilical vein immediately after birth. The fetuses were classified according to the gas analysis result. They were considered abnormal when pH <7.20 and BE < -6 mmol/l. A receiver operator characteristic (ROC) curve analysis was performed to examine the relationship between S/A ratio and fetal acidemia. RESULTS: sixty pregnant women in the period of January 1998 to January 2003 were selected. In the moment of the study the gestational age varied from 25 to 33 weeks, with an average of 29.7 weeks (±1.8 weeks). All of the fetuses presented the "brain sparing phenomenon". Among them 14 presented abnormal gas analysis at birth and 46 presented normal gas analysis. The prevalence of fetuses with abnormal gas analysis in the studied material was 23.33%. Significant association was observed between the abnormal ductus venosus velocimetry and abnormal gas analysis at birth (chi2 = 784.44, p < 0.00001) in preterm fetuses with "brain sparing phenomenon". The best cut-off point of the S/A ratio (where the ROC curves bent) was 3.4. CONCLUSION: fetal acidemia in preterm fetuses with "brain sparing phenomenon" may be noninvasively identified by Doppler measurement of the ductus venosus when the S/A rises above 3.4.
Summary
Revista Brasileira de Ginecologia e Obstetrícia. 2004;26(5):363-367
DOI 10.1590/S0100-72032004000500004
OBJECTIVE: evaluation of fetomaternal hemorrhage (FMH) in patients who would need Rh alloimmunization with anti-D immunoglobulin (300 mug) prophylaxis after early miscarriage. METHOD: we included in the study Rh (D) negative blood group patients with positive or unknown Rh (D) partners, who had had a miscarriage up to 12 weeks of gestation, and had been admitted to hospital for uterine curettage. After this procedure 5 ml of venous blood was collected from the patients and the rosette test was applied to screen which patients would need quantitative determination of fetal blood transferred to the maternal circulation, by the Kleihauer-Betke test (K-B). RESULTS: out of 26 patients evaluated the rosette test was positive in one , who showed an FMH of 1.5 ml in the K-B test. CONCLUSIONS: the dose of anti-D immunoglobulin used in cases of miscarriage up to 12 weeks of gestation should be substantially reduced. The availability of preparations of 50 mug is recommended, for a more inexpensive and rational treatment.
Summary
Revista Brasileira de Ginecologia e Obstetrícia. 2004;26(5):377-382
DOI 10.1590/S0100-72032004000500006
OBJECTIVE: to describe ultrasonographic alterations in fetuses infected with Toxoplasma gondii, correlating them with neonatal prognosis. METHODS: between June 1997 and May 2003, 150 pregnant women with suspected toxiplasmosis were examined. Acute infection was confirmed in 72 (48%) of these pregnant women and congenital toxoplasmosis was diagnosed in 12 (16%) fetuses. Prenatal diagnosis was established by polymerase chain reaction in the amniotic fluid. All the patients received antiparasitic therapy. Ultrasound examination was performed every fortnight and all the infants were evaluated during their first year of life. RESULTS: ultrasonographic changes were observed in eight fetuses. All of them showed symmetric bilateral ventricular enlargement that was associated with periventricular calcifications in five cases. Other changes as hepatic calcification, hepatomegaly, polyhydramnium, and pericardial effusion were less frequent. Among these fetuses, four were stillborn and three showed sequelae (chorioretinitis and neuro-psychomotor retardation). The four fetuses that showed normal ultrasonography had a satisfactory development. CONCLUSION: There was a high incidence of ultrasonographic changes in fetuses with congenital toxoplasmosis, mainly brain damage. Other changes as hepatomegaly and pericardial effusion were less frequent and were related to a systemic infection. The prognosis of these fetuses seems to be correlated with the presence of these lesions mainly because they had high mortality ratio and among the survivors the incidence of sequelae was high. The non-symptomatic fetuses evolved in a favorable way without developing sequelae. These results highlight the value of ultrasonographic examination of these fetuses in order to establish a prognosis and allow the elaboration of a suitable post-natal procedure.
Summary
Revista Brasileira de Ginecologia e Obstetrícia. 2004;26(5):383-389
DOI 10.1590/S0100-72032004000500007
OBJECTIVE: to evaluate the measurement of uterine height in order to predict fetal growth restriction (FGR), according to a local curve. METHODS: from July 2000 to February 2003, 238 high-risk pregnant women were submitted to uterine height measurements between the 20th and the 42nd week of gestation. The gestational age of all the women was well known, confirmed by early ultrasound. Fifty (21%) women gave birth to infants considered small for their gestational age. The measures were performed by a single observer, who took 1617 uterine height measurements, from the upper border of the symphysis pubis to the fundus uteri, using tape measurement. The diagnosis of FGR was confirmed after birth according to the Ramos's curve. The women were divided into two groups according to their infant's birth weight and the data were statistically analyzed by the Fisher's exact test or Kruskal-Wallis's test. The sensitivity (SE), specificity (SP), positive predictive value (PPV), and negative predictive value (NPV) were calculated. The test for two proportions with normal approximation was performed to analyze the continuous variables. RESULTS: one measurement below the 10th percentile, according to gestational age, resulted in SE = 78.0%, SP = 77.1%, PPV = 47.6%, and NPV = 88.8% for the identification of FGR. If one measurement was below the 5th percentile, the SE, SP, PPV, and NPV were 64.0, 89.9, 62.7 and 90.4%, respectively. CONCLUSIONS: one measurement below the 10th percentile for the gestational age, according to the local curve, proved to be a good predictor of FGR.
Summary
Revista Brasileira de Ginecologia e Obstetrícia. 2004;26(5):391-398
DOI 10.1590/S0100-72032004000500008
OBJECTIVE: to analyze the maternal blood pressure and heart rate variation of primigravid women during labor and early puerperium. METHODS: sixty primigravid women were included in the study, and submitted to ambulatory blood pressure monitoring (ABPM) with SpaceLabs 90207 monitor during labor and the first 12 h of puerperium. The records of blood pressure and heart rate were done every 15 min during labor and every 30 min during the first 12 h of puerperium. Three periods during labor (until cervix dilated 7 cm, cervix dilated between 8 cm and total dilatation, and delivery period) and two during puerperium (first and twelfth hours), were analyzed. First of all the results were analyzed without considering the kind of analgesia used and then the patients were divided into three groups, according to the anesthetic technique: local, lumbar extradural or subarachnoid. Results were analyzed by one-way analysis of variance (ANOVA) and paired Student's t-test for blood pressure and heart rate in each group during labor and puerperium. The nonpaired Student's t-test was used to compare different groups. A p value < 0.05 was regarded as statistically significant. RESULTS: when the results were analyzed without considering the analgesic procedure, the values of systolic blood pressure during labor were significantly higher than in early puerperium. During labor, systolic blood pressure values were higher in the periods of later cervical dilatation and delivery than during early cervical dilatation. In the 12th h of puerperium the systolic blood pressure was lower than in the first hour. Diastolic blood pressure did not change during labor and was higher than in early puerperium. Heart rate increased during labor and decreased during puerperium. The systolic and diastolic blood pressure and heart rate were the same both in local or lumbar extradural anesthesia groups; however, in the subarachnoid group the systolic and diastolic blood pressure did not change during labor. CONCLUSIONS: labor increased systolic blood pressure and heart rate. During labor, systolic and diastolic blood pressure were higher than in early puerperium. Both blood pressure and heart rate significantly fell from the first to the 12th hour of puerperium. The different anesthetic techniques did not affect blood pressure or heart rate, as compared with the primigravid group when the anesthetic technique was not taken into consideration.